Bryant Geothermal Heat Pump Systems

50YEW

21

Residential Products Technical Guide

Warranty Information

The 2010 standard warranty applies to units ordered on or after 
July 1, 2010. See Bryant’s 2010 Limited Express Residential Warranty 
Certifi cate CA234 for specifi c coverage and limitation. 

Bryant residential class heat pumps are backed by a ten-year limited 
warranty on all unit parts, including the following accessories when 
installed with Bryant units: Flow Controllers & Electric Heaters.

Bryant goes even further to back up its commitment to quality 
by including a service labor allowance for the fi rst fi ve years on 
refrigeration circuit components and two years on all other parts, 
auxiliary heaters and geothermal pumping modules.

The Optional Extended Factory Service Labor Allowance Warranty 
offers additional length of term protection to the consumer by 
offsetting service labor costs for 10 years.

To order this warranty, contact your Bryant distributor. This coverage 
must be purchased within 90 days of unit installation. See Limited 
Express Extended Labor Warranty Certifi cate CA235 for details.

Accessories & Warranty

Accessories & Options

Hot Water Mode Option

An optional mode to provide domestic hot water shall be 
provided. This mode shall include a factory-installed, internal 
secondary heat exchanger and a factory-installed potable 
water, bronze circulating pump. This option shall provide an 
additional set of water connections for the potable domestic 
hot water and shall be completely factory installed and wired. 
An external sensor shall be provided to sense the domestic 
water storage tank temperature.

Internal Source and Load Pumps / Internal 
Expansion Tanks

Optional Source pump(s), Load pump, and expansion tank(s) 
shall be factory installed and wired to help lower installation 
costs and labor.  When installed at the factory, pumps are 
controlled by the MPC.
 

Variable Speed Floor Pump Connection

An optional relay and line voltage lugs shall be provided for a 
variable speed radiant fl oor system pump. Some radiant fl oor 
systems utilize a variable speed pump on the fl oor system, 
which changes fl ow based upon the number of zones open 
or closed. Since the pump has built-in controls, only a power 
supply is needed. 

Cupro-Nickel Heat Exchanger

An optional corrosion resistant CuNi coaxial heat exchanger 
shall be factory installed in lieu of standard copper 
construction (Source heat exchanger only).

Flow Controller (fi eld installed)

A self-contained module shall provide all fl uid pumping, fi ll 
and connection requirements for ground-source closed-
loop systems up to 20 GPM [76 l/m]. The Flow Controller 
shall provide 1” pump isolation valves/3-way service valves. 
Pump heads shall be removable from the volute for easy 
replacement. The Flow Controller shall be enclosed in a 
polystyrene case and fully insulated with urethane foam to 
prevent condensation. The Flow Controller shall have a 5- year 
warranty on all parts.

Hose Connection Kit (fi eld installed)

An accessory hose kit shall provide 150psi [1034 kPa] 1” 
rubber hose with brass fi ttings equipped with service pressure/
temperature ports for connection between the unit and Flow 
Controller.

Содержание 50YEW

Страница 1: ...GT PW 50YEW Water To Water Series WATER TO WATER PURON SYSTEMS SIZE 010 10 kW Revised May 8 2013...

Страница 2: ...Contents Unit Features 3 Model Key 5 Rated Equipment Performance Efficiencies 6 Performance Data 7 Physical Data 9 Dimensions 10 Electrical Data 11 Wiring Diagrams 12 Engineering Guide Specifications...

Страница 3: ...Installation Advantages Hinged front access door and 3 removable panels for ease of installation and service Galvanized steel construction with protective powder coat paint and hinged front access do...

Страница 4: ...utdown 11 Powder Coated Galvanized Steel Cabinet and Front Access Panel For Long Life Taupe Metallic 9 Fully Insulated Water and Refrigerant Lines 7 Optional Full Condensing Hot Water Generation With...

Страница 5: ...s w Expansion Tanks C Copper Source Braze Plate Load No DHW W CXM Y CXM w VSFP 50 A 0 1 0 C W 3 1 1 4 5 6 7 8 9 10 11 12 Unit Size Voltage Controls 1 Single Pack Domestic Packaging 1 Current Revision...

Страница 6: ...tes typical radiant floor application temperatures Ratings at 40 C 104 F are based upon AHRI ISO Standard 13256 2 all other ratings are based upon Standard EN 14511 2 50YEW010 Model Ground Loop Heat P...

Страница 7: ...5 1 0 2 2 110 35 1 3 15 24 4 123 0 3 8 0 4 0 9 34 2 3 06 23 8 119 4 3 3 0 8 1 9 130 32 1 3 92 18 7 141 8 2 6 0 3 0 7 31 0 3 82 18 0 138 5 2 4 0 7 1 6 8 3 0 7 1 7 50 48 9 1 13 45 0 68 1 12 7 0 8 1 7 4...

Страница 8: ...0 34 2 3 64 21 8 139 8 2 8 1 7 4 0 36 3 3 27 25 1 133 6 3 3 3 5 8 0 70 6 75 0 6 1 3 50 49 5 1 96 42 8 78 1 7 4 1 9 4 3 54 1 1 79 48 0 70 0 8 9 3 7 8 6 70 46 9 2 41 38 7 96 8 5 7 1 8 4 2 51 3 2 20 43 8...

Страница 9: ...tic Hot Water Connection Size FPT in 3 4 Maximum Working Pressure Water Side Base Unit PSIG kPa 500 3445 DHW Option PSIG kPa 145 999 Internal Source Pump w Expansion Tank PSIG kPa 145 999 Internal Loa...

Страница 10: ...Access Plugs 1 2 3 4 5 6 A Depth B Width C Height D Source Outdoor Water In E Source Outdoor Water Out F Load Indoor Water In G DHW Water Out H Load Indoor Water Out J DHW Water In K Low Voltage L Low...

Страница 11: ...Min Max Voltage Compressor Load Pump FLA Source Pump FLA ISBP Pump FLA Total Unit FLA Min Circuit Amps Max Fuse HACR Qty RLA LRA THW010 G 208 230 60 1 197 254 1 20 7 81 1 07 1 07 22 8 28 45 1 07 1 07...

Страница 12: ...50YEW 12 50YEW Water To Water Series Bryant Whatever It Takes 50YEW010 Electrical Wiring Diagram 230 60 1 96B0108N05 Electrical Wiring Diagrams EW Water To Water Ser...

Страница 13: ...Bryant Geothermal Heat Pump Systems 50YEW 13 Residential Products Technical Guide 50YEW010 Electrical Wiring Diagram 230 60 1 96B0108N05...

Страница 14: ...50YEW 14 50YEW Water To Water Series Bryant Whatever It Takes 50YEW010 Electrical Wiring Diagram 230 60 1 VSFP 96B0108N06...

Страница 15: ...Bryant Geothermal Heat Pump Systems 50YEW 15 Residential Products Technical Guide 50YEW010 Electrical Wiring Diagram 230 60 1 VSFP 96B0108N06...

Страница 16: ...50YEW 16 50YEW Water To Water Series Bryant Whatever It Takes 50YEW010 Electrical Wiring Diagram 230 60 1 DHW 96B0108N08...

Страница 17: ...Bryant Geothermal Heat Pump Systems 50YEW 17 Residential Products Technical Guide 50YEW010 Electrical Wiring Diagram 230 60 1 DHW 96B0108N08...

Страница 18: ...50YEW 18 50YEW Water To Water Series Bryant Whatever It Takes 50YEW010 Electrical Wiring Diagram 230 60 1 DHW VSFP 96B0108N09...

Страница 19: ...Bryant Geothermal Heat Pump Systems 50YEW 19 Residential Products Technical Guide 50YEW010 Electrical Wiring Diagram 230 60 1 DHW VSFP 96B0108N09...

Страница 20: ...perheat over the entire fluid temperature range with minimal hunting The coaxial heat exchangers and refrigerant suction lines shall be insulated to prevent condensation at low liquid temperatures Ele...

Страница 21: ...ter and shall be completely factory installed and wired An external sensor shall be provided to sense the domestic water storage tank temperature Internal Source and Load Pumps Internal Expansion Tank...

Страница 22: ...vision water side high pressure switches added 01 June 10 Various Warranty Paint Nomenclature Updates 30 Mar 10 All Misc format physical data and electrical data 30 Mar 10 Decoder Page Decoder Updated...

Отзывы: