Congratulations! In light of rising
energy costs, the 368RAN Vari-
able Speed Low-Boy Oil Furnace
is among the soundest investments
today’s homeowner can make.

Your new furnace is truly a tri-
umph of technology in home heat-
ing. Its unique silencer within the
heat exchanger, insulated cabinet,
and rubber blower mounts make it
among the quietest units on the
market. Variable speed technology
creates more comfortable heating
and cooling cycles, allows you to
economically run a constant fan,
and eliminates temperature differ-
ence throughout the house. The
combustion chamber is stainless
steel for long life and it heats up
quickly resulting in higher energy
efficiency.

With only minimal care, your new
furnace will deliver many years of
money-saving home comfort and
enjoyment. Spend just a few min-
utes with this manual to learn the
operation of your new furnace and
the small amount of maintenance
it takes to help keep it operating at
peak efficiency year after year.

 

INSTALLATION DATA

 

Date Installed

Dealer Name

Address

City

State

Zip

Telephone

 

FURNACE

 

Product No.

Model No.

Serial No.

 

SPLIT-SYSTEM

 

OUTDOOR UNIT:

Product No.

Model No.

Serial No.

INDOOR COIL:

Product No.

Model No.

Serial No.

 

ACCESSORIES

 

Product No.

Model No.

Serial No.

 

1

 

MODEL 368RAN LOW-BOY FURNACE

Содержание 368RAN

Страница 1: ...ier WARNING If the information in this manual is not followed exactly a fire or explosion could result causing property damage personal injury or loss of life Do not use this furnace if any part has b...

Страница 2: ...erature differ ence throughout the house The combustion chamber is stainless steel for long life and it heats up quickly resulting in higher energy efficiency With only minimal care your new furnace w...

Страница 3: ...num Stainless steel combustion chamber Heat exchanger designed and shaped to effi ciently transfer heat from furnace into the home Supply air plenum Fully insulated internal walls minimize heat loss H...

Страница 4: ...ng equipment Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters All other operations must be per formed by trained service person nel Observe safety...

Страница 5: ...he main burner does not ignite within 30 sec from the call for heat the control will lock out The red button on top of the con trol must be depressed for 3 sec in order to reset the control The contro...

Страница 6: ...vided as standard equipment with furnace See Fig 2 To inspect clean and or replace air filters fol low these steps 1 Turn off electrical supply to fur nace See Fig 11 2 Remove blower access door in r...

Страница 7: ...Inspect all vent piping inside struc ture for deterioration and vent termi nations outside the structure for blockage Check oil pipes leading to and inside of your furnace for leaks Inspect and clean...

Страница 8: ...trol must be depressed for 3 sec in order to reset the control Check for obstructions around the vent termination If the furnace still fails to operate call your service representative For your conven...

Отзывы: