background image

Fig.

7—Wiring

Diagram

A96380

INDOOR

BLOWER

MOTOR

BR

BR

CAP

T

GND

LINE V

24 V

LINE V

24 V

BK

BL

BR

GR

OR

RD

RD/BK

VI

WH

YL

F

T

CAP

AL

L

GND

BLACK

BLUE

BROWN

GREEN

ORANGE

RED

RED/BLACK STRIPE

VIOLET

WHITE

YELLOW

LOW SPEED FAN SWITCH

TRANSFORMER

STARTING CAPACITOR

AUXILARY LIMIT

LIMIT

GROUND

LEGEND

PRINTED CIRCUIT

BOARD WIRING

FACTORY WIRING

FIELD WIRING

ORANGE WIRE NUT

GROUND

=  TERMINAL PROVIDED

=  TERMINAL NOT PROVIDED

WIRE NUT CONNECTIONS

FACTORY WIRING

UNUSED

MOTOR

LEADS

B

U

R

N

E

R

1

1

1

4

7

23

3

X

H

U

M

C

45

6

N

7

S

2

E

A

C

C

O

N

T

C

O

O

L

H

E

A

T

H

M

L

C

F

1

2

2

1

3

5

4

6

8

7

9

1

2

12

60 Sec.

12

90 Sec.

DELAY  OFF  DIP  SWITCH  SETTINGS

12

1212

120 Sec.

12

150 Sec.

L1(H)

N3

S2

K2

K2

K1

K1

N2

N2

L1

0

L2(N)

LOW SPEED HEAT 

CONNECTION

MEDIUM SPEED 

HEAT CONNECTION

GND

COOL

HIGH

LOW

MED

HIGH

MED

LOW

HEAT

HEAT

CONSTANT

COOL

CN6-9

CN6-1

C

LIMIT

CN6-6

CN6-3

S1

N1

X

N4

S3

CN6-2

CN6-7

CN6-8

BURNER

MOTOR

PRIMARY

ACCESSORY

120VAC

24VAC

LIMIT SENSE

OIL ELECTRONIC FAN TIMER

GND

TRANSFORMER

CN6-4

CONSTANT

LOW SPEED

FAN SWITCH

LOW SPEED

FAN SWITCH

UNUSED MOTOR LEAD

L2

UNUSED MOTOR LEAD

CIRCULATION BLOWER

CIRCULATION 

BLOWER

CIRCULATION 

BLOWER

K1, K2

CONTROL

K3

TSTAT

R

W

Y

G

C

T1         T2

PRIMARY

115 VAC 1

ø 

60HZ POWER SUPPLY

(FUSED DISCONNECT ON HOT LEG)

(1) MAKE FIELD POWER SUPPLY CONNECTIONS TO BLACK AND WHITE WIRES CAPPED 

      WITH ORANGE WIRE NUTS.

(2) WARNING--- UNIT MUST BE GROUNDED. WIRING MUST CONFORM TO N.E.C. AND 

      LOCAL CODES. IN CANADA WIRING MUST CONFORM TO CURRENT CSA 22.1 CANADIAN

      ELECTRICAL CODE PART 1 AND/OR LOCAL CODES.

(3) IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED,

     IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF 

     AT LEAST 105

°

 C AND BE A MINIMUM OF 16 GA. AWG COPPER STRAND WIRE. USE 

     COPPER WIRE ONLY FOR FIELD WIRING.

(4) CONNECT REQUIRED MOTOR LEAD TO HEAT TERMINAL ON CIRCUIT BOARD TO DELIVER 

      A TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

(5) SET THE HEAT ANTICIPATOR ON THE THERMOSTAT AT .2 AMPS.

(6) FOR ELECTRICAL LOAD AMPERES, BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE 

      SIZE SEE FURNACE MODEL LABEL.

(7) HUM TERMINAL IS 115V.

H

M

L

C

INDOOR

BLOWER

MOTOR

LOW SPEED HEAT

CONNECTION DETAIL

BR

BR

CAP

UNUSED

MOTOR

LEADS

B

U

R

N

E

R

1

123

34

S

2

E

A

C

C

O

N

T

C

O

O

L

H

E

A

T

F

1 2 3 4

RD

RD

RD/BK

WH

BK

BL

YL

RD

RD

L

FIXED COOL 

ANTICIPATOR

ADJUSTABLE

HEATING

ANTICIPATOR

TEMP

FALL

TYPICAL THERMOSTAT

COOL

OFF

FAN

AUTO

ON

HEAT

W

R1

W1

Y1

GW

R

Y

C

I

YR

G

DELAY OFF

SELECTION

DIP SWITCH

DELAY OFF

SELECT

CN6

VI

BK

BURNER

MOTOR

WH

WH

CN6

WH

OR

YL

BL

BK

L1

L2

ORANGE

FLAME DETECT

ENLARGED TOP VIEW

CAD CELL

(BLACK)

(WHITE)

INTERUPTED OIL PRIMARY CONTROL

T1

T2

BK

OR

COOLING

CONTACTOR

(IN AIR 

CONDITIONER, 

IF USED)

WH

BK

L1 (H)

L2 (N)

GND

BL

YL

WH

- - -

- - -

- - -

- - -

- - -

- - -

1 2 3 4

BK

WH

RD

RD

YL

BL

Honeywell

NOTES:

 POWER SUPPLY

115 VAC /1Ø 60 HZ

(FUSED DISCONNECT ON HOT LEG)

MEDIUM SPEED

HEAT CONNECTION

ST9103

N5

ELECTRONIC AIR

CLEANER

(OPTIONAL)

EAC

HUM

N6

HUMIDIFIER (OPTIONAL)

SEE

NOTE 7

FACTORY SET

HEATING SPEED

105-- MED (M)

125-- MED (M)

155-- HIGH (H)

—11—

Содержание 362AAN

Страница 1: ...BURNER WHEN EXCESS OIL HAS ACCUMULATED WHEN THE FURNACE IS FULL OF VAPOR OR WHEN THE COMBUSTION CHAMBER IS VERY HOT WARNING For use with grade 2 Fuel Oil maximum Do not use Gasoline Crankcase Oil or a...

Страница 2: ...e avoided Such contamination would include the follow ing ammonia chlorine hydrogen sulfide halogenated hydrocarbons carbon tetrachloride cleaning solvents hydrochloric acid water softening chemicals...

Страница 3: ...rmal to achieve proper combustion 5 Lockouts on start up II DUCT WORK RECOMMENDATIONS The proper sizing of warm air ducts is necessary to ensure satisfactory furnace operation Duct work should be in a...

Страница 4: ...flue pipe must not extend into chimney but be flush with inside wall 9 The chimney must extend 3 ft above highest point where it passes through the roof of a building and at least 2 ft higher than an...

Страница 5: ...draft over fire draft CO2 and stack tempera tures MUST be used in order to obtain proper air band setting Although all of the above measurements are re quired for optimum setup and efficiency data th...

Страница 6: ...quipment requires certain expertise me chanical skills tools and equipment If you do not possess these do not attempt to perform any maintenance on this equipment other than those procedures recom men...

Страница 7: ...akage This could lead to furnace damage oil fumes sooting and severe bodily harm 8 Reconnect flue pipe 9 Reinstall filter and blower door 10 Turn on power to unit and readjust burner for proper operat...

Страница 8: ...onnect motor wires at terminal block on motor 6 Remove blower from unit 7 Reverse items 1 through 6 to reinstall blower Refer to wiring diagram Fig 7 of these instructions or diagram located on inside...

Страница 9: ...ON PANEL SUPPLY DUCT CLEAN OUT PORTS RETURN DUCT 1 3 C A96309 DIMENSIONS IN UNIT SIZE UNIT DIMENSIONS DUCT SUPPLY OPENING FLUE DIAMETER RETURN DUCT Width Depth Height A B C D E F G H 036105 22 52 33 2...

Страница 10: ...Fig 6 Barometric Damper Locations A95117 FIG A FIG G FIG D FIG L FIG B FIG C FIG J FIG H FIG K POOR WRONG WRONG WRONG WRONG WRONG BAROMETRIC DAMPER LOCATIONS GOOD LOCATIONS BAD LOCATIONS 10...

Страница 11: ...CONFORM TO N E C AND LOCAL CODES IN CANADA WIRING MUST CONFORM TO CURRENT CSA 22 1 CANADIAN ELECTRICAL CODE PART 1 AND OR LOCAL CODES 3 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE...

Страница 12: ...ing season you should perform the following procedures WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life 1...

Отзывы: