Refer to Fig. 6 for field application wiring and Fig. 7 for unit wiring.
With power disconnected to the unit, check all electrical connections
for tightness. Tighten all screws on electrical connections. If any
smokey or burned connections are found, disassemble the connection,
clean all parts, strip wire, and reassemble properly and securely.

Reconnect electrical power to the unit and observe unit through 1
complete operating cycle. Electrical controls are difficult to check
without proper instrumentation. A good voltmeter is needed to check
for correct operation of controls and wiring.

If the furnace fails to operate, check the following items before calling
for service:

1. Is the thermostat set correctly to

call for heat?

2. Are the electrical and gas supplies ON?

3. Are the filters clean?

Refer to the Trouble Analysis chart in this manual for further
information.

Fig. 6—Heating and Cooling Application Wiring Diagram

A91338

Fig. 5—Pilot and Burner Flames

A84076

—4—

Содержание 349HAZ

Страница 1: ... CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage WARNING Never store anything on near or in contact with the furnace such as 1 Spray or aerosol cans rags brooms dust mops vacuum cleaners or other cleaning tools 2 Soap powders bleaches waxes or other cleaning compounds plastic or plastic containers gasoline kero sene cigarette ...

Страница 2: ... filters and let dry Oiling or coating of filters is not recommended or required for factory supplied filters 7 Reinstall filters with cross mesh binding facing blower 8 Replace blower access door and reinstall 4 screws 9 Turn ON electrical supply to furnace II BLOWER MOTOR AND WHEEL MAINTENANCE For long life economy and high efficiency clean accumulated dirt and grease from blower wheel and motor...

Страница 3: ...n flat work surface and clean burner ports Use a soft brush to loosen dirt then vacuum 6 Using a small rubber mallet gently tap each burner opening to loosen any debris in heat exchanger cells 7 Brush each heat exchanger cell using a nylon heat exchanger brush with a long flexible handle 8 Vacuum each heat exchanger cell and burner box with a crevice tool attachment 9 Check position and alignment ...

Страница 4: ... observe unit through 1 complete operating cycle Electrical controls are difficult to check without proper instrumentation A good voltmeter is needed to check for correct operation of controls and wiring If the furnace fails to operate check the following items before calling for service 1 Is the thermostat set correctly to call for heat 2 Are the electrical and gas supplies ON 3 Are the filters c...

Страница 5: ...Fig 7 Wiring Diagram A91349 5 ...

Страница 6: ...ns Check all wiring and connections repair as nec essary No gas at main burners Check if main gas valve is opening Check for broken or loose wiring connections If no deficiency is found replace gas valve Flame rollout shutoff switch activated Check venting system for blockage correct im proper venting condition Flame probe or connecting lead shorted or open Correct electrical shorting or open circ...

Отзывы: