DIMENSIONS

2-7/16" 

1-1/8" 

28-7/8" 

(733mm) 

25-1/4" 

22-9/16" 

JUNCTION BOX 
LOCATION 

7/8" DI A 

ACCESSORY 

1/2" DIA THERMOSTAT 

WIRE ENTRY 

3-15/16" 

LEFT HAND GAS 

ENTRY 

33-5/16" 

24-7/8" 

5-1/2" 

7/8" DIA. ACCESSORY 

11/16" 

21-5/8" 

BOTTOM INLE T 

1-11/16" 

13/16" 

11/16" 

4-13/16" 

AIRFLOW 

19" 

OUTLE T 

13/16" 

11/16" 

8-9/16" 

VENT OUTLE T 

5 PLACES (TYP) 

3-3/4" 

1-3/4" DIA.RIGHT HAND 
GAS ENTRY 

7/8"  DIA.  K.O.  WIRE  ENTRY 

SIDE INLE T 

14-7/8" 

7/8" DIA. ACCESSORY 

1-1/4" 

1" 

22-1/16" 

(FLUE COLLAR) 

5-15/16" 

24" 

CASING 

1-5/16" 

1/2"  DIA.  K.O.THERMOSTAT 
WIRE ENTRY 

ALTERNAT E 

JUNCTION BOX 

LOCATIONS (TYP) 

26-1/8" 

1-1/2" 

7-3/4" 

9-5/8" 

11-1/2" 

5-1/2" 

 

(664mm) 

(641mm) 

(573mm) 

(22mm) 

(846mm) 

(17mm) 

(549mm) 

(610mm) 

(43mm) 

(140mm) 

(632mm) 

(17mm) 

(140mm) 

(95mm) 

(21mm) 

(122mm) 

(217mm) 

(62mm) 

(33mm) 

(29mm) 

(483mm) 

(13mm) 

(44mm) 

(22mm) 

(22mm) 

(38mm) 

(560mm) 

(25mm) 

(32mm) 

(378mm) 

(17mm) (197mm) 

(244mm) 

(292mm)

(21mm) 

A04037

1. Two additional 7/8--in. (22 mm) dia. knockouts are located in the top plate.
2. Minimum return--air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
3. Minimum return--air opening at furnace.

a. For 800 CFM--16--in. (406 mm) round or 14--1/2 x 12--in. (368 x 305 mm) rectangle.

b. For 1200 CFM--20--in. (508 mm) round or 14--1/2 x 19--1/3 in. (368 x 491 mm)rectangle.

c. For 1600 CFM--22--in. (559 mm) round or 14--1/2 x 22--1/16--in. (368 x 560 mm) rectangle.

d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a

combination of 1 side and the bottom, or the bottom of single side inlets. The use of both side inlets, a combination of one side and the bottom, or the bottom only

will ensure adequate return air openings for airflow requirements above 1800 CFM.

313AAV/JAV

UNIT SIZE

A

CABINET

WIDTH

IN (MM)

D

SUPPLY WIDTH

IN (MM)

E

BOTTOM

RETURN WIDTH

IN (MM)

F

TOP VENT

OUTLET

IN (MM)

VENT

CONNECTION

SIZE

(see Notes 1 & 2)

MEDIA CABINET

SIZE

IN (MM)

024045

14---3/16 (360)

12---9/16 (319)

12---11/16 (322)

9---5/16 (237)

4

16 (406)

048070

17---1/2 (445)

15---7/8 (403)

16---1/8 (410)

11---9/16 (294)

4

16 (406)

048090

21 (533)

19---3/8 (492)

19---1/2 (495)

13---5/16 (338)

4

20 (508)

060110

21 (533)

19---3/8 (492)

19---1/2 (495)

13---5/16 (338)

4

20 (508)

060135

24---1/2 (622)

22---7/8 (581)

23 (584)

15---1/16 (383)

4 (Note 1)

24 (610)

1. 135 size furnaces require 5---in. (127 mm) vents. Use a 4---5 in. (102---127 mm) vent adaptor between furnace and vent stack.
2. See installation instructions for complete installation requirements.

313AA

V/

JA

V

Содержание 313AAV PLUS 80X

Страница 1: ...onditioning Heating and Refrigeration Institute s standard coil only ratings when paired with selected Bryant evaporator coils STANDARD FEATURES S ECM blower motor included S Noise elimination combust...

Страница 2: ...UAL RESET LIMIT SWITCHES GAS VALVE FLUE COLLECTOR BOX PRESSURE SWITCH INDUCER MOTOR ASSEMBLY CAPACITOR POWER CHOKE WHERE USED A02259 NOTE The 313AAV JAV Furnaces are factory shipped for use with natur...

Страница 3: ...1 speed Air Conditioner deg F C Auto Changeover T6 NAC T2 NAC For use with 1 speed Air Conditioner deg F C Auto Changeover T6 NHP T2 NHP For use with 2 speed Air Conditioner deg F C Auto Changeover T6...

Страница 4: ...PH X X X X X Combustible Floor Base KGASB0201ALL X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X Vent Extension Kit KGAVE0101DNH X X X X X Chimney Adapter Kit KGACA02014FC X X X X Chimney Adapter...

Страница 5: ...Gas Maximum Inlet Pressure in wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft 610 M For elevations above 2000 ft 610 M reduce ratings 4 percen...

Страница 6: ...lations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in single wall vent must be us...

Страница 7: ...9 SEE NOTES 1 2 4 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL LEFT HORIZONTAL LEFT HORIZONTAL LEFT HORIZ...

Страница 8: ...40 1065 1005 925 865 790 1 1280 1205 1140 1055 990 910 840 760 695 630 060135 Bottom or Side s 5 2295 2240 2185 2125 2070 2005 1925 1805 1670 1545 4 1725 1660 1605 1545 1460 1395 1340 1285 1230 1170 3...

Страница 9: ...4 1 2 x 12 in 368 x 305 mm rectangle b For 1200 CFM 20 in 508 mm round or 14 1 2 x 19 1 3 in 368 x 491 mm rectangle c For 1600 CFM 22 in 559 mm round or 14 1 2 x 22 1 16 in 368 x 560 mm rectangle d Fo...

Страница 10: ...in the horizontal position Line contact only permissible between lines formed by intersections of the Top and two Sides of the furnace jacket and building joists studs or framing DOWNFLOW POSITIONS D...

Страница 11: ...V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES Connect Y terminal in furnace as shown for proper blower operation Some therm...

Страница 12: ...________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard...

Отзывы: