background image

12

GUIDE SPECIFICATIONS

Gas Furnace

310AAV/JAV

General

SYSTEM DESCRIPTION

Furnish a _________________ fixed capacity gas-fired

furnace for use with natural gas or propane (factory

authorized conversion kit required for propane); furnish

cold air return plenum.

QUALITY ASSURANCE

Unit will be designed, tested and constructed to the

current ANSI Z 21.47/CSA 2.3 design standard for

gas-fired central furnaces.

Unit will be 3rd party certified by CSA to the current

ANSI Z 21.47/CSA 2.3 design standard for gas-fired

central furnaces.

Unit will carry the CSA Blue Star

R

label.

Unit efficiency testing will be performed per the current

DOE test procedure as listed in the Federal Register.

Unit will be certified for capacity and efficiency and

listed in the latest AHRI Consumer’s Directory of

Certified Efficiency Ratings.

Unit shall carry the current Federal Trade Commission

Energy Guide efficiency label.

DELIVERY, STORAGE AND HANDLING

Unit shall be shipped as single package only and is

stored

and

handled

per

unit

manufacturer’s

recommendations.

WARRANTY (for inclusion by specifying engineer)

U.S. and Canada only. Warranty certificate available

upon request.

Products

EQUIPMENT

Components shall include: slow-opening gas valve to

reduce ignition noise, regulate gas flow, with electric

switch gas shut-off; flame proving sensor, hot surface

igniter, pressure switch assembly, flame rollout switch,

blower and inducer assembly, 40va transformer;

low--voltage (heating) (heating/cooling) thermostat.

Blower Wheel and Blower Motor

Galvanized blower wheel shall be centrifugal type,

statically and dynamically balanced. Blower motor of PSC

type shall be permanently lubricated with sealed bearings,

of _______hp, and shall be multiple-speed direct drive.

Blower motor shall be soft mounted to the blower scroll to

reduce vibration transmission.

Filters

Furnace may have reusable-type filters. Filter shall be

_______ in (x) _______in. (mm).

Casing

Casing shall be of .030 in. (.76 mm) thickness

minimum, pre--painted galvanized steel.

Inducer Motor

Inducer motor shall be soft mounted to reduce vibration

transmission.

Draft Safeguard Switch

Draft Safeguard Switch (blocked vent safeguard) shall

be factory installed to reduce the possibility of vent gas

infiltration due to a blocked or restricted vent pipe.

Heat Exchangers

Heat exchangers shall be a 4-Pass 20 gage aluminized

steel of fold-and-crimp sectional design when applied

operating under negative pressure.

Controls

Control shall include a micro-processor non--volatile

memory based integrated electronic control board with at

least 11 service troubleshooting codes displayed via

enhanced flashing LED diagnostic light on the control, a

self-test feature that checks all major functions of the

furnace

within

one

minute,

and

a

replaceable

automotive-type

circuit

protection

fuse.

Multiple

operational settings available including, separate blower

speeds for heating, cooling, and continuous fan.

Continuous fan speed may be adjusted from the

thermostat. Cooling airflow will be selectable between 350

or 400 CFM per ton of air conditioning.

OPERATING CHARACTERISTICS

Heating Capacity shall be ________ Btuh input;

________ Btuh output capacity.

Fuel Gas Efficiency shall be 80% AFUE.

Air delivery shall be ___________ CFM minimum at

0.50 In. W.C. external static pressure.

Dimensions shall be: depth __________ in. (mm);

width _________ in. (mm); height_________in. (mm)

(casing only). Height shall be_________in. (mm) with

A/C coil and _____________in. (mm) overall with

plenum.

ELECTRICAL REQUIREMENTS

Electrical supply shall be 115 volts, 60 Hz,

single--phase (nominal). Minimum wire size shall

be_________AWG; maximum fuse size or circuit breaker

shall be __________Amps.

SPECIAL FEATURES

Refer to section of the product data sheet identifying

accessories and descriptions for specific features and

available enhancements.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

E

2010 Bryant Heating & Cooling Systems

D

7310 W. Morris St.

D

Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 09/10

Replaces: PDS 310A.45.5

Catalog No. PDS310A.45.6

310AA

V

/J

A

V

Содержание 310AAV

Страница 1: ...rizontal Right Horizontal Left Downflow Thirteen different vent options S Compact design only 33 1 3 in 846 mm tall S Microprocessor based smart control center Adjustable heating air temperature rise...

Страница 2: ...additional 7 8 in 22 mm diameter holes are located in the top plate 2 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendations for e...

Страница 3: ...69 DE S I GN C E R T I F I E D Always Ask For Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products go to...

Страница 4: ...y Standard CONTROLS Limit Control SPST Heating Blower Control Solid State Time Operation Burners Monoport 2 2 3 3 3 4 4 Gas Connection Size 1 2 in NPT GAS CONTROLS Gas Valve Redundant Mfr White Rodger...

Страница 5: ...Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid State Time Operation Burners Monoport 4 5 5 5 6 6 7 Gas Connection Size 1 2 in NPT GAS CONTROLS Gas Valve Re...

Страница 6: ...diately after exiting the furnace except when Downflow Vent Guard is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in 102 mm single wall vent must be used inside furnace c...

Страница 7: ...8 9 HORIZONTAL RIGHT A02070 SEE NOTES 1 2 4 7 8 9 HORIZONTAL RIGHT A02069 SEE NOTES 1 2 4 7 8 9 HORIZONTAL LEFT A02064 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02065 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL...

Страница 8: ...Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGBVG0101DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X Chimney Adapte...

Страница 9: ...angeover 7 Day Programmable Temperature and Humidity Control T6 PRH ZONING CONTROL SELECTION Zone Perfect 3 Zone kit ZONEBB3ZAC01 ZONEBB3ZHP01 Zone Perfect Plus 2 Zone kit Temperature and Humidity Con...

Страница 10: ...810 785 725 048110 Bottom or Side s High Med High Med Low 2035 1745 1530 1965 1710 1515 1880 1650 1470 1790 1560 1400 1680 1450 1310 1495 1340 1215 1365 1205 1095 1215 1090 990 1075 955 830 875 750 67...

Страница 11: ...11 310AAV JAV...

Страница 12: ...um pre painted galvanized steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard Switch Draft Safeguard Switch blocked vent safeguard shall be factory...

Отзывы: