The 310AAV/310JAV 4--Way Multipoise Gas Furnace was

designed by Bryant dealers for Bryant dealers.

Applications are

easy with 4--way Multipoise design, through--the--furnace
downflow venting, 13 different venting options, and a design for

easy service access. An inner blower door is provided for tighter
sealing in sensitive applications. The 310AAV/310JAV furnace is

approved for use with natural or propane gas, and the 310JAV is
approved for use in Low NOx Air Quality Management Districts.

STANDARD FEATURES

S

Noise elimination combustion system

S

Four--position furnace: Upflow, Horizontal Right,
Horizontal Left, Downflow

Thirteen different vent options

S

Compact design only 33--1/3 in. (846 mm) tall

S

Microprocessor based “smart” control center

Adjustable heating air temperature rise
Enhanced diagnostics with LED and reflective sight glass,
non--volatile fault code memory, and self--test feature
On--board fuse for transformer protection

S

Patented blocked--vent safeguard to ensure proper furnace
venting

S

Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1--In. W.C.
with all present air inlets, air outlets, and condensate drain
port(s) sealed.

S

HYBRID HEAT

r

Dual Fuel System compatible

S

All models are chimney friendly when used with accessory
vent kit

S

Twinning in Upflow, Downflow, and Horizontal

S

Perfect Light

t

Igniter

S

Residential installations eligible for consumer financing
through the Comfort Credit Program

Содержание 310AAV

Страница 1: ...rizontal Right Horizontal Left Downflow Thirteen different vent options S Compact design only 33 1 3 in 846 mm tall S Microprocessor based smart control center Adjustable heating air temperature rise...

Страница 2: ...additional 7 8 in 22 mm diameter holes are located in the top plate 2 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendations for e...

Страница 3: ...69 DE S I GN C E R T I F I E D Always Ask For Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products go to...

Страница 4: ...y Standard CONTROLS Limit Control SPST Heating Blower Control Solid State Time Operation Burners Monoport 2 2 3 3 3 4 4 Gas Connection Size 1 2 in NPT GAS CONTROLS Gas Valve Redundant Mfr White Rodger...

Страница 5: ...Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control Solid State Time Operation Burners Monoport 4 5 5 5 6 6 7 Gas Connection Size 1 2 in NPT GAS CONTROLS Gas Valve Re...

Страница 6: ...diately after exiting the furnace except when Downflow Vent Guard is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in 102 mm single wall vent must be used inside furnace c...

Страница 7: ...8 9 HORIZONTAL RIGHT A02070 SEE NOTES 1 2 4 7 8 9 HORIZONTAL RIGHT A02069 SEE NOTES 1 2 4 7 8 9 HORIZONTAL LEFT A02064 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02065 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL...

Страница 8: ...Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGBVG0101DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X Chimney Adapte...

Страница 9: ...angeover 7 Day Programmable Temperature and Humidity Control T6 PRH ZONING CONTROL SELECTION Zone Perfect 3 Zone kit ZONEBB3ZAC01 ZONEBB3ZHP01 Zone Perfect Plus 2 Zone kit Temperature and Humidity Con...

Страница 10: ...810 785 725 048110 Bottom or Side s High Med High Med Low 2035 1745 1530 1965 1710 1515 1880 1650 1470 1790 1560 1400 1680 1450 1310 1495 1340 1215 1365 1205 1095 1215 1090 990 1075 955 830 875 750 67...

Страница 11: ...11 310AAV JAV...

Страница 12: ...um pre painted galvanized steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard Switch Draft Safeguard Switch blocked vent safeguard shall be factory...

Отзывы: