Table 3 – Required Liquid Line Temperatures

_

F

LIQUID PRESSURE AT

SERVICE VALVE (PSIG)

REQUIRED SUBCOOLING TEMPERATURE (° F)

8

10

12

14

16

18

251

76

74

72

70

68

66

259

78

76

74

72

70

68

266

80

78

76

74

72

70

274

82

80

78

76

74

72

283

84

82

80

78

76

74

291

86

84

82

80

78

76

299

88

86

84

82

80

78

308

90

88

86

84

82

80

317

92

90

88

86

84

82

326

94

92

90

88

86

84

335

96

94

92

90

88

86

345

98

96

94

92

90

88

354

100

98

96

94

92

90

364

102

100

98

96

94

92

374

104

102

100

98

96

94

384

106

104

102

100

98

96

395

108

106

104

102

100

98

406

110

108

106

104

102

100

416

112

110

108

106

104

102

427

114

112

110

108

106

104

439

116

114

112

110

108

106

450

118

116

114

112

110

108

462

120

118

116

114

112

110

474

122

120

118

116

114

112

486

124

122

120

118

116

114

499

126

124

122

120

118

116

511

128

126

124

122

120

118

Table 4 – Superheat Charging (Heat Pump Only)

OUTDOOR TEMP (° F)

EVAPORATOR ENTERING AIR TEMPERATURE (° F WB)

50

52

54

56

58

60

62

64

67

68

70

72

74

76

55

11

11

12

12

12

13

17

20

24

24

25

25

25

25

60

6

6

7

7

7

7

12

16

21

22

23

23

23

23

65

---

---

---

---

---

3

7

12

18

19

21

21

22

22

70

---

---

---

---

---

---

---

7

14

16

18

20

20

20

75

---

---

---

---

---

---

---

3

11

13

16

18

18

19

82

---

---

---

---

---

---

---

---

*6

8

12

15

16

17

85

---

---

---

---

---

---

---

---

4

7

11

14

15

16

90

---

---

---

---

---

---

---

---

---

4

8

12

14

15

95

---

---

---

---

---

---

---

---

---

---

6

10

12

14

100

---

---

---

---

---

---

---

---

---

---

4

8

11

12

105

---

---

---

---

---

---

---

---

---

---

3

6

9

11

110

---

---

---

---

---

---

---

---

---

---

---

5

7

10

115

---

---

---

---

---

---

---

---

---

---

---

3

6

8

*Optimum performance point, 82 ° F outdoor ambient and (80 ° F dry bulb),( 67 ° F wet bulb) indoor conditions. (DOE B Test Conditions)
Where a dash (--- ---) appears do not attempt to charge system under these conditions or refrigerant slugging may occur. Charge must be weighed in.

Note

: Superheat ° F is at low---side service port, Allow a tolerance of ± 3 ° F

Note

: Indoor dry bulb between 70 ° F and 80 ° F

Table 5 – Required Suction--Line Temperature

SUPERHEAT TEMP

˚

F)

SUCTION PRESSURE AT SERVICE PORT (PSIG)

107.8

112.2

116.8

121.2

126

130.8

138.8

140.8

145.8

0

35

37

39

41

43

45

47

49

51

2

37

39

41

43

45

47

49

51

53

4

39

41

43

45

47

49

51

53

55

6

41

43

45

47

49

51

53

55

57

8

43

45

47

49

51

53

55

57

59

10

45

47

49

51

53

55

57

59

61

12

47

49

51

53

55

57

59

61

63

14

49

51

53

55

57

59

61

63

65

16

51

53

55

57

59

61

63

65

67

18

53

55

57

59

61

63

65

67

69

20

55

57

59

61

63

65

67

69

71

22

57

59

61

63

65

67

69

71

73

24

59

61

63

65

67

69

71

73

75

26

61

63

65

67

69

71

73

75

77

28

63

65

67

69

71

73

75

77

79

30

65

67

69

71

73

75

77

79

81

223A

/225B

Содержание 24APA

Страница 1: ...nnect switch must be in the OFF position There may be more than 1 disconnect switch Lock out and tag switch with a suitable warning label CUT HAZARD Failure to follow this caution may result in person...

Страница 2: ...LOCATIONS in mm A B C 26 X 26 660 X 660 9 1 8 231 8 4 7 16 112 7 21 1 4 539 8 31 1 2 X 31 1 2 800 X 800 9 1 8 231 8 6 9 16 166 7 24 11 16 627 1 35 X 35 889 X 889 9 1 8 231 8 6 9 16 166 7 28 7 16 722...

Страница 3: ...apor and liquid service valves Service valves are closed from factory and ready for brazing After wrapping service valve with a wet cloth tubing set can be brazed to service valve using either silver...

Страница 4: ...h other or any sheet metal Pay close attention to feeder tubes makings sure wire ties on feeder tubes are secure and tight Be sure field wiring complies with local and national fire safety and electri...

Страница 5: ...n personal injury Wear safety glasses protective clothing and gloves when handling refrigerant and observe the following S Front seating service valves are equipped with Schrader valves CAUTION ENVIRO...

Страница 6: ...rost board see Fig 10 in the ON position When Quiet Shift switch is placed in ON position and a defrost is initiated the following sequence of operation will occur Reversing valve will energize compre...

Страница 7: ...lve pres sure 6 To obtain required subcooling temperature at a specific li quid line pressure add refrigerant if liquid line temperature is higher than indicated or reclaim refrigerant if temperature...

Страница 8: ...21 22 23 23 23 23 65 3 7 12 18 19 21 21 22 22 70 7 14 16 18 20 20 20 75 3 11 13 16 18 18 19 82 6 8 12 15 16 17 85 4 7 11 14 15 16 90 4 8 12 14 15 95 6 10 12 14 100 4 8 11 12 105 3 6 9 11 110 5 7 10 1...

Страница 9: ...ce valve stem caps to 1 12 turn past finger tight 4 Leave Owner s Manual with owner Explain system opera tion and periodic maintenance requirements outlined in manual 5 Fill out Dealer Installation Ch...

Страница 10: ...ion line filter drier in liquid line S POE oils absorb moisture rapidly Do not expose oil to atmosphere S POE oils may cause damage to certain plastics and roofing materials S Wrap all filter driers a...

Отзывы: