Bryan Boilers DR Series Скачать руководство пользователя страница 2

Low initial cost, high operating efficiency
deliver substantial return on investment

K.

 Internal water-cooled

furnace with low heat re-
lease rate.

L.

 Steam boilers with extra

large drum with high steam
release area ensure stable
water level and dry steam.

M.

 Pressurized design:

inner fireside casing con-
structed of heavy gauge
steel, completely sealed,
lined with high temperature
insulation and refractory.

A.

 Water side or steam side interior accessible for

cleanout and inspection, front and rear openings, up-
per and lower drums.

B.

 Large volume water leg downcomers promote  rapid

internal circulation, temperature equalization and effi-
cient heat transfer.

C. 

Boiler tube and furnace area access panel: heavy

gauge steel-lined with high temperature ceramic fiber
and insulation, bolted and tightly sealed to boiler frame.

D.

 Single side access; combustion chamber, tubes and

burner head are completely accessible from one side
simplifying maintenance and minimizing floor space.

E.

 Minimum sized flue vent.

F.

 Control panel: all controls installed with connections to

terminal strip.

G.

 Forced draft, flame retention head type burner. Effi-

cient combustion of oil or gas, quiet operation.

H.

 Heavy steel boiler frame, built and stamped in accor-

dance with the appropriate ASME Boiler Code.

I.

 Heavy gauge steel boiler jacket with rust-resistant zinc

coating and enamel finish, insulated with fiberglass to
insure exceptionally cool outer surface.

J.

 Bryan bent water tubes are flexible, individually re-

placeable without welding or rolling. Never more than two
tube configurations.

True “flexible water
tube” design

High quality steam for
heat or process

Pressurized firing for
high efficiency

A

L

F

G

D

K

B

C

J

E

M

H

I

Bryan DR Series Boiler Specifications

 DR250-S

250 (73)

200 (59)

6 (59)

206 (93)

66 (6.1)

1,150 (522)

DR350-W

350 (103)

280 (82)

8 (82)

292 (86)

9 (86)

66 (6.1)

1,150 (522)

  DR350-S

350 (103)

280 (82)

8 (82)

288 (131)

66 (6.1)

1,150 (522)

 DR450-W

450 (132)

360 (106)

10 (98)

376 (110)

11 (110)

66 (6.1)

1,150 (522)

  DR450-S

450 (132)

360 (106)

10 (98)

371 (168)

66 (6.1)

1,150 (522)

 DR650-W

650 (190)

520 (152)

15 (147)

543 (159)

16 (159)

103 (9.6)

1,650 (748)

  DR650-S

650 (190)

520 (152)

15 (147)

536 (243)

103 (9.6)

1,650 (748)

 DR850-W

850 (249)

680 (199)

20 (196)

710 (208)

21 (208)

103 (9.6)

1,650 (748)

  DR850-S

850 (249)

680 (199)

20 (196)

701 (318)

103 (9.6)

1,650 (748)

BOILER

MODEL

(1)

INPUT

MBH
(KW)

OUTPUT@ 80%

EFFICIENCY

(2)

MBH (KW)

HP (KW)

OUTPUT@ 83.5%

EFFICIENCY

(3)

MBH (KW)

HP (KW)

STEAM OUTPUT

(4)

LBS/HR (KG/HR)

HEATING

SURFACE

SQ. FT. (M

2

)

APPROX.

SHIP

LBS. (KG)

NOTES:

(1) W = Water / S = Steam
(2) Output and horsepower based on boiler industry standard of 80% of input.
(3) Output and horsepower based on an average natural gas combustion efficiency of 83.5% for hot water boiler. Actual combustion efficiencies for oil will be higher.
(4) Lbs. steam per hour from and at 212°F.

Содержание DR Series

Страница 1: ...150 FDG Form No 3710 Rev 6 04 Originators of the Flexible Water Tube design Bryan Flexible Water Tube DR Series Steam Water Boilers 250 000 to 850 000 BTUH Forced Draft Gas Oil or Dual Fuel Fired Water Boiler DR850 W FDGO ...

Страница 2: ...esteelboilerjacketwithrust resistantzinc coating and enamel finish insulated with fiberglass to insure exceptionally cool outer surface J Bryan bent water tubes are flexible individually re placeablewithoutweldingorrolling Nevermorethantwo tubeconfigurations True flexible water tube design High quality steam for heat or process Pressurized firing for high efficiency A L F G D K B C J E M H I Bryan...

Страница 3: ... ofheattransferanduniform temperature throughout the boiler Eliminating stress damage causedbyunequaltemperaturedistribu tion is especially important for heating systems particu larly where intermittent or continuous low temperature water returns may be encountered OPTIONAL EQUIPMENT EXTRA COST 1 Manual reset high limit control 2 Manual reset low water cutoff 3 Auxiliary low water cutoff 4 Combina...

Страница 4: ...rnet www bryanboilers com Fax 765 473 3074 E mail bryanboilers iquest net STEAM BOILER DIMENSIONS in inches cm A B C D E F G H I J K L Boiler Overall Floor to Width Length Height Gas Train Supply Nozzle Return Flue Flue Min Tube Clearance Model Length Flow Outside of Over Connection Conn Size Location Removal for Servicing Number Nozzle Jacket Jacket Jacket Approx 15 psi 150 psi Clearance Burner D...

Отзывы: