background image

Detach and return within 30 days.
Name:  ______________________________________________________________________
Address:  ____________________________________________________________________
City: ___________________________State: __________ Zip Code :_____________________
Phone :  _____________________________Email: __________________________________
Date Purchased:  ______________________________________________________________

Would you like to receive a Brunton catalog?
(   )Yes   (   )No

Please let us know where you purchased your Vapor-AF?
Store Name:  _________________________________________________________________
City:  ___________________________ State:  __________ Zip Code:  ___________________
(   ) Online site ______________________   (   ) Catalog _______________________________
(   )  Gift  (   ) Brunton  (   ) Other __________________________________________________

Do you own another Brunton product?
(   )  Yes. Product:  ___________________________  (   ) No

VII. Turning the Vapor-AF oFF (Flip-stop)

The Flip-stop pump is designed to prevent fuel spillage and release air pressure from the fuel 
bottle prior to disconnecting from the stove.  
1. Leaving control handle fully on, flip the fuel bottle until OFF is read on the pump.  

    • The fuel feed hose of the pump will start to feed air instead of fuel.  All fuel remaining in the 

      pump, hose and burner will be burnt and used.  
2. After a short time (full output) the flame will automatically burnout.  

    • When the flame has gone out, air pressure is automatically released through the burner jet, 

      helping to clean the jet.  Let stove depressurize for a couple of minutes.  

    • Wait until all pressure has been released, and let the stove cool off prior to disconnecting 

      the canister valve. 

Note:  If the stove is not to be moved or disconnected, you can turn the stove off by closing the 
control handle fully, without depressurizing the bottle.  Since air pressure is still in the bottle, the 
moment the control handle is turned on fuel will escape through the burner jet.  ALWAYS use the 
flip-stop to depressurize bottle before transporting.

5)  Cleaning & Maintenance

I. Maintenance

1. Brunton recommends carrying a Vapor-AF maintenance kit for field repairs and maintenance. 
2. Use only Vapor-AF parts when replacing/repairing the stove.  Never modify!

II. Cleaning Burner Jet & Burner Maintenance

1. Turn OFF stove valve and wait until stove has completely cooled.  Remove flame spreader.  
Pierce the jet hole with cleaning needle. 

    • All types of fuel contain impurities which may clog the jet.  This is noted by poor burner 

      performance, despite adequate pressure in the fuel bottle.    

    • Make a habit of cleaning the burner jet prior to setting it up, and packing out.

2. If stove output is still poor, it may be necessary to clean the jet again. Remove the burner 
plate, and unscrew the jet using the Multi-tool.  Carefully prick the jet orifice using the cleaning 
needle, then reassemble the jet and burner plate.

6)  Vapor-AF Parts

1    Flame spreader

2    Jet

3    Inner burner cup
4    Priming wick
5    Burner cup
6    Metallic part
7    Bottom burner cup screw (M3x8)
8    Valve spindle
9    O-rings for valve spindle (P-3)
10  Spindle nut
11  Control handle base
12  Control handle
13  O-rings for swivel (P-3)
14  Swivel holder
15  Fuel hose assembly
16  O-ring (P-8)
17  Valve gasket
18  Pot support
19  E-ring
20  Center pin for pot support

WARRANTY

Brunton warrants this product to be free of defects in workmanship and materials for the lifetime 
of the original owner, and is nontransferable.  If you have any problems with your Vapor-AF, the 
stove should be returned to the dealer or sent to Brunton, 2255 Brunton Court, Riverton, WY 
82501 U.S.A.  Please contact Brunton at the number below to obtain a RA#.  Clean food and 
soot from stove before shipping. Shipping cost to Brunton is the responsibility of the purchaser.  
Return postage will be paid by Brunton. Please return this warranty card to Brunton as a proof 
of purchase.  This warranty does not cover damage caused by accident, misuse, abuse, or 
tampering.  A nominal charge will be assessed to repair such damage.

BRUNTON
Attn.: Warranty Repair   

307.857.4700

2255 Brunton Court 

 

[email protected]

Riverton, WY 82501 

 

www.brunton.com

LIMITS oF LIABILITY

Brunton assume no responsibility for any inconvenience, loss, or injury, direct or consequential 
damage arising from possession or use of the goods. This warranty gives you specific legal 
rights which may vary from state to state. Check with your local state about your rights.

21  Flame spreader fastener
22  Fuel pump body
23  Fuel bottle o-ring (P-24)
24  Fuel filter
25  Filter cap
26  Filter holder
27  O-ring for plunger (P-11.2)
28  Plunger
29  Screw for filter fastener (M3 x 6)
30  Spring fastener
31  Valve spring
32  Check valve O-ring (SM-3)
33  Check valve
34  O-rings (P-8)
35  Pump adapter
36  Connector to #43 canister valve
37  Air pipe
38  Fuel pipe
39  Flathead screwdriver for nozzle installation
40  Flathead screwdriver

Warranty Registration - Vapor-AF

41  Bottle opener
42  Cleaning needle
43  Canister valve

Отзывы: