background image

2

Battery Charger: Connecting to Envoy

Start with the AC input power to the battery charger switched OFF. Connect the red 24 VDC output con-

nector of the battery charger to the matching red charger connection port on the left hand side cover of the 

Envoy. Make sure the green ‘POWER’ LED on the left-hand side cover of the Envoy indicates that the 

lane machine power is ON. The switch ON the power to the battery charger. This sequence assures that 

the charger always starts with the proper mode necessary to the stat of the battery discharge.
The red ‘CHARGE’ LED located on the left-hand side cover of the Envoy, should turn ON only after it 

sense voltage from a properly connected battery charger. This indicates the START of the battery charging 

process.  Switch OFF the power to the battery charger before removing the red charger connector from 

the left-hand side cover of the Envoy. The red ‘CHARGE’ LED does not turn off if the charger is discon

-

nected. This red ‘CHARGE’ LED remains ON until the lane machine prepares to run a lane or the power 

is turned off. The red ‘CHARGE’ LED should then turn ON again after it senses voltage from a properly 

connected battery charger.  Refer to 

Figure 2.

  (1)  GREEN POWER LED MUST BE ON TO 

CHARGE AND MONITOR BATTERIES

  (2)  CONNECT RED CHARGER CONNECTOR 

TO PORT ON LEFT HAND SIDE COVER

  (3)  RED CHARGER LED TURNS ON TO 

INDICATE START OF CHARGING BATTERY

Figure 2

Battery Charger: Connecting to the MAX

Start with the AC input power to the battery charger switched OFF. Connect the red 24 VDC output con-

nector of the battery charger to the matching red charger connection port on the left hand side cover of the 

MAX. Make sure the green ‘POWER’ LED on the left-hand side cover of the MAX indicates that the lane 

machine power is ON. The switch ON the power to the battery charger. This sequence assures that the 

charger always starts with the proper mode necessary to the stat of the battery discharge. The MAX will 

begin monitoring the charging cycle when the DC output voltage reaches 26.8 VDC.  The MAX can be 

charged with the machine power off, however the system will not be able to monitor the charge.

Remember, always connect the battery charger to the lane machine when not running lanes:

 

•   The battery charger is designed to remain connected to the lane machine whenever not running 

the lane machine. It will keep the batteries in optimal condition and will not overcharge them.

 

•  Leaving the lane machine on for any extended time without connecting the battery charger will 

slowly discharge the batteries and reduce their capacities.