LED DIAGNOSTIC CHART
POWER
(RED)
CHARGE
(YELLOW)
FLOAT
(GREEN)
FAULT
(RED)
CHARGER STATUS
ON
(2 sec.)
ON
(2 sec.)
ON
(2 sec.)
ON
(2 sec.)
initial power up
ON
OFF
OFF
OFF
charger not connected to battery (AC power
ON, no battery connected)
ON
OFF
OFF
ON
output shorted, battery reversed
ON
FLASH
OFF
OFF
soft-start charging
ON
ON
OFF
OFF
charger at maximum voltage/delivering
maximum current
ON
ON
FLASH
OFF
batteries close to being fully charged
FLASH
OFF
OFF
OFF
batteries connected; AC disconnected
ON
OFF
ON
OFF
batteries fully charged
ON
OFF
OFF
FLASH batteries defective/heavily sulfated
ON
OFF
OFF
FLASH internal over temperature shutdown
RECYCLE
BATTERIES IN
ACCORDANCE WITH
REGULATIONS IN
FORCE IN YOUR
AREA.
LED DIAGNOSTIC CHART and TROUBLESHOOTING
Platform does not operate
• Gate/door open. Close gate/door.
properly in the UP or the
• E-Stop button inadvertently depressed. Pull out E-stop button.
DOWN direction.
Platform controls do
• Key switch turned to OFF. Turn key to ON.
not operate.
• E-Stop button inadvertently depressed. Pull out E-stop button.
• Batteries fully discharged. Fully charge batteries, inspect
and/or replace.
• Internal circuit breaker tripped. Reset circuit breaker.
Charger requires a long
• Check batteries. Replace if necessary.
time to charge batteries
between uses.
Platform operates very
• No AC power. Check plug.
slowly.
• Batteries not fully charged.
Allow batteries to recharge.
PROBLEM
POSSIBLE CAUSE / SOLUTION
TROUBLESHOOTING