8
User manual IRON DOG 02 (1.1)
© 2013 Brunner GmbH
Werte
1)
nominal heat output
kW
7
flue gas stream
g/s
7,6
flue gas temperature (at port)
°C
353
necessary draft
Pa
12
consumption/h
kg
2
space heating capacity
m
3
50 - 90
degree of efficiency
%
80,6
combustion air consumption
m
3
/h
15
appliance data
dimension (h x w x d)
mm
730 x 540 x 610
glass pane surface (h x w)
mm
245 x 105
combustion chamber opening (h x w)
mm
250 x 210
flue diameter
Rückwand
permitted fuel quantity
kg
1,5 - 2,5
combustion chamber dept
cm
40
recommended log length
cm
25 / 33
cast iron weight
kg
150
required minimum clearances
to the side wall
cm
80
to the rear wall (with insulation panel)
cm
30
to the rear wall (without insulation panel)
cm
40
approvals
CE nach EN 13240
1) the data was determined in an EN 13240 test with a chimney stove with a horizontal smoke tube connection, tube length 35 cm
.