PREAMP TUBES

The preamp tubes are used to preamplifier the signal. They usually last the entire life of the amplifier.

The possible problems of these kind of tubes are:  microphonics and noise.

Microphonics

The microphonics is the ability of a tube to reproduce external vibrations further the signal.
This phenomenon can be much more evident in high gain stage like the distortion channels.

Lightly tapping on the glass side of the preamp tubes, while the head is on, you' ll hear a stroke through the
speaker, this is normal don' t worry.
But if you hear hi frequencies (ringing or squealing) and in some case a distorted sound, it means that the tube is
microphonics.

You will note that the first tube is more subject to reproduce this stroke more than the others, because it' s at
the begin of the preamplification chain.

Noise

Tube has an own intrinsic floor noise that comes from its work and construction.

During tube life this noise may increase creating a sort of a ringing or squealing.
In these two cases, you have to find the defective tube and repleace it with a new one.

The preamp tube doesn't need  to be selected, (normally this control has been made by the constructor), but be sure
to replace with good quality tubes.
We suggest thay you use tubes of same brand and model.

POWER TUBES

Power tubes are the last amplification stage before the out trasformer and speaker out, and they can get exhausted.

Normally a power tube working in A/B class lasts 800 - 1000 hours. It depends also on the volume used.

In an amplifier with same power, in A class, the tube lasts 600 - 800 hours. In this class work tubes are more stressed.

When replace power tubes

You can recognize an exhausted tube because there's a loss of power and volume. Sound has not the same impact,
in particular on low frequencies.

Main faults on this kind of tube are :
- short inside the tube. In this case normally the HT fuse will blow.
- tube light off. It's easy to recognize this problem tube because you can't see any light inside the tube.
- tube become glowing. In this case there's an increase of noise (hum) and sound will be distorted.

In all the above cases tubes can' t be fixed, and have to be replaced.

If the problem tube has worked more that 1 year, we suggest that you replace all power tubes, this to guarantee the
best performance of your amp.

If the problem tube has less than 1 year you can replace only that one.

Warning!!

You have to mount only selected and matched tubes, with the same 

characteristics of the tube supplied on your

aplifier. See the ''Matching Reference'' label on the tube.

If you mount tubes with different ''Matching Reference'' is necessary to adjust the Bias, to let the amp work properly.

GENERAL INFORMATION

Содержание Star-T-rack

Страница 1: ......

Страница 2: ...within this radical dual power design I have chosen 6L6GC tubes for this amplifier model The preamplifier section needs no elaborate introduction 4 channels that range from the totally transparent to...

Страница 3: ...IA power dimension system AUXILIARY CONTROLS DEPTH controls for L R power channels LOOP serial parallel with separated variable controls Mix L R Send level max 0 85Vrms Clean 2 2Vrms Other Return leve...

Страница 4: ...rear panel The channel switching can be manual push buttons or by footswitch supplied or MIDI All the three systems can be used at the same time The channel is controlled by GAIN BASS MID EDGE MASTER...

Страница 5: ...A Speaker jacks Pls don t mismatch the labeled impedance to avoid damage These switches select the two power classes of the amp AB class delivers 50W with a modern style sound while A class delivers 2...

Страница 6: ...until you ll find the correct balance between the direct sound and the effect sound The 0 position means only direct sound while 100 position means only effect sound Serial SERIAL USE Use the effect p...

Страница 7: ...ew the four A B C D 2 Remove aluminium corners E ed F 3 Remove G panel 4 Fix the efx to the rack rails 5 Cover the rack rails with the two black blockets H e J founded into the packing 6 Fix the corne...

Страница 8: ...0 8 6 2 0 4 10 6 2 0 4 10 8 8 6 2 0 4 10 8 6 2 0 4 10 8 6 2 0 4 10 6 2 0 4 10 6 0 4 10 0 100 80 20 0 100 80 20 LINE ON STDBY BASS MID EDGE GAIN MASTER BOOST MASTER 6 0 4 10 8 6 0 4 10 CLEAN OVERDRIVE...

Страница 9: ...T MASTER OVERDRIVE EFX mix L R VOLUME BOOST BOOST DRIVE BASS MID EDGE VOLUME 8 6 0 4 10 6 2 0 4 10 8 6 2 0 4 10 8 6 2 0 4 10 8 6 2 0 4 10 6 2 0 4 10 8 8 6 2 0 4 10 8 6 2 0 4 10 8 6 2 0 4 10 6 2 0 4 10...

Страница 10: ...se tubes of same brand and model POWER TUBES Power tubes are the last amplification stage before the out trasformer and speaker out and they can get exhausted Normally a power tube working in A B clas...

Страница 11: ...necessary to adjust the balance between the DIRECT DRY and the EFFECT WET PARALLEL LOOP In a Parallel Loop only a part of the direct sound passes throught the loop effect without going out from the Se...

Страница 12: ...MIDI CONNECTIONS GENERAL INFORMATION...

Страница 13: ...HEAD Speaker L 8 16 16 8 Speaker R HEAD Speaker L 8 16 16 8 Speaker R HEAD Speaker L 8 16 16 8 Speaker R HEAD Speaker L 8 16 16 8 Speaker R HEAD Speaker L 8 16 16 8 Speaker R CABINET 4x12 CABINET 2x12...

Страница 14: ...or moist hands or feet Do not allow children or incompetents to use the appliance Do not leave inflammable materials near to the appliance Do not pull up the appliance by control knobs Read carefully...

Отзывы: