background image

point by point training

CLEANPOINT      

BHC

317.923.3211
WWW.BHCINC.COM
ISO 9001:2015 CERTIFIED

Connect Tank

44

Rotate the nozzle to select 

the medium (80 micron) 

setting.
BHC recommends 80 

micron nozzles for use with 

our disinfectants. 

Adjust Nozzle

55

Spray

Turn on the unit and squeeze the trigger. 
Optimum sprayer distance is 2 feet (24 inches).

Avoid overspray on fabric or clothing.

6

6

Clean Up

Remove tank. Refer to product 

label for proper disposal of unused 

solution.
It is important to rinse the tank and 

spray clean water through the sprayer 

at the end of each day to prevent 

buildup.
For preventative maintenance: Rinse 

nozzle with hot soapy water 1-2x per 

week. (Instructions for nozzle removal 

and wrench included in case.) 

7

7

Charge Battery

11

This side is fully 

illuminated when charged.

(90 minute charge time)

Note: If wet, the battery will not work or charge. Keep 
liquids from touching battery and charger contacts. 
Wipe battery and charger contacts with dry cloth 
immediately if they come into contact with liquids.

Use Directions - Handheld Unit

Remove Cap/Tank

22

Small

(40)

Large
(110)

Medium
(80)

BruTab 6S

Product No.

3.3g is 161021-8G

Victory 

Handheld Unit

Product No.

VSHAND

Fill Tank

33

BruTab 6S:

If using pre-diluted BruTab 6S 

solution, fill the tank with disinfectant 

solution.
For Disinfectant Solution use 3.3g tablet as follows:
• Fill reservoir with 1 quart (32 oz) clean water.
  •  For minimum 2153 ppm (1 minute Norovirus) 

add 2 tablets.

  •  For minimum 1076 ppm (10 minute Hospital Use) 

add 1 tablet.

  •  For minimum 4306 ppm (4 minute C. diff, 1 minute 

Bloodborne Pathogens) add 4 tablets. 

  •  For minimum 5382 ppm (4 minute TB) add 5 tablets.
Allow to completely dissolve before using.

See product label for full directions for use.

BruTab 6S

Product No. 

161021-8G

Rotate collar to unlock 

icon position.

Pull locking ring to 

remove.

Lift unit off the tank.

Align tank grooves into 

slide rail, lower machine 

onto tank. (Listen for a 

"click")
Rotate collar to lock icon 

position.

For equipment questions and 

service contact: 

Victory Innovations Tech Support 

800.741.7788