Width old: 0000
Width new:____
8. Input of the width (four-digit), e.g.: 0700.
Welding section:_
9. Input of the welding section (one-digit).
This question is only asked in the case of
a correspondingly large joint, e.g.: 1.
Data: 1 001/1234
10. Summary of the data entered.
5678/0315/0700/1
The order: data record no./PIN/project
no./joint no./DN/width/welding section.
Should a value be incorrect, it is possible to
move to the point with the R key and
change the value with the C key.
OK
Machine ready
Press the START key
11. The machine is ready for welding.
START
Welding running
12. The machine begins to check the
connected joint.
Welding running
13. As soon as the welding time 00:01 is
shown, the power transfer begins. The
heating wire is heated.
A
Welding running
14. The weld pool temperature can be
047 00:01
queried during welding with the key A. The
key A must be pressed until the value is
shown. The value shown is the last weld
pool temperature saved. It is, therefore,
possible that the same value is shown
twice one after the other if there has been
no significant change.
Welding
15. The end of the welding process is
finished
indicated by this display and an acoustic
signal.
150/04:50
Shows the weld pool temperature and
welding time.
The inputs 3 to 8 described above are then proposed for the following welding
processes of the day with the exception of the joint number. The proposed values
can be changed by pressing the key C. If the values are to be taken over for the next
welding process, it is only necessary to press OK.