Terminal Protective Housing AC-2127
Instruction
AC-2127def V02 15.4. 2014 Subject to change without prior notice C105006001
Cable entries
Mounted side A
6x M16x1,5 mm for cable 6-10 mm
2x M25x1,5 mm for cable 14-18 mm
Mounted side B
6x M16x1,5 mm for cable 3-7 mm
Enclosed
9x M16x1,5 mm Blind fitting
2x M25x1,5 mm Blind fitting
Material
Brass nickle-plated
Sealing
Perbunan
Accessories
AC-215 Series terminals
The protective housing can be extended with the terminals AC-215. Instead of the oscillator the ter-
minals are mounted on the DIN rail and secured with the enclosed holders.
Assembly
Mount housing
do not attach to vibrating parts of the machine
observe temperature at place of installation (radiant heat)
Observe the mounting instructions for non-contacting displacement sensors
1.
Mount the oscillator on the DIN rail and secure it with the enclosed holders.
2.
Steel protective hose:
If the cables are laid in steel protective conduit the heavy-gauge conduit threads have to be
removed and be replaced by adequate cable glands threads for steel protective conduit.
3.
Entries that have not been used must be blanked off by means of the appropriate blanking
plugs.
4.
When closing the fitting take care of the tightness of the seal lip.
1. Cable
2. Compression nut
3. Clamping insert
4. Inner sealing ring
5. Cable shield
6. Intermediate adapter
Figure 1
Connecting the cable screen to the
conduit fitting
1
2
3
4
5
6