Appx. 2 Command Description
Cmd
Command Description
Config Length
0x00(1byte)
Get Sensor Configuration
(Only for unconfirmed downlink)
0 bytes
0x00(1byte)
Set update event interval when the
sensor is in moving mode.
*Note: little-endian format.
2 bytes
0x01(1byte)
Set keep alive interval when the
sensor is in stationary mode.
*Note: little-endian format.
2 bytes
0x02(1byte)
Set g-sensor timeout interval when the
sensor is in moving mode.
*Note: little-endian format.
2 bytes
Payload Content
Command content
Ex:
001E00 ||
01201C ||
023C00
00 1E00 =>
Set update event interval when the sensor is in moving mode.
: 0x001E -> 30 sec
01 201C
=>
Set keep alive interval when the sensor is in stationary mode.
: 0x1C20 ->
7200 sec
02 3C00
=>
Set g-sensor timeout interval when the sensor is in moving mode.
: 0x003C ->
60 sec
© 2019 Browan Communications Inc. All rights reserved.
13