3. Operation
3.1 Transport Mode
Sensors are shipped with a plastic battery insulating pull tab that must be removed
before the operation.
3.2 Default Operation
During default operation, the device will send an environmental status message to the network
once there is a sufficient delta in the environmental conditions or 5 minutes of inactivity. The
precise trigger values can be found in 4.1.1.
4. Messages
LoRaWAN Packets for this device use port 103.
4.1 Status
4.1.1 Triggers
Packet Triggers: 5-minute inactivity, ±2°C delta(environment temp), ±5 %RH
Delta, ±25 IAQ Index Delta.
The device will scan the environment every 5
minutes.
4.1.2 Payload
Port
103
Payload Length
11 bytes
Bytes
0
1
2
3
4
5
6
7
8
9
10
Field
Status
Battery
Temp.
(PCB)
RH
CO
2
VOC
IAQ
Temp.
(environment)