background image

6.1.5 Factory check code 

4D4483B1. 

Checksum of the factory production line. 

 

6.1.6 Model Name 

MODEL:TBDW100. 

Fixed code, not including in QR code. 

6.2 PE Bag & Back Label Label Barcode

 

 

 

PE Bag Label 

Back Label 

 

Definition of Back Label and PE Bag Barcode Label: 
GS1 DataMatrix 

The GS1 Application Identifier (21) indicates that the GS1 Application Identifier data 
field contains a serial number.  

The GS1 Application Identifier (92) assigned to the company’s internal information is 
DevEUI. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

© 2019 Browan Communications Inc. All rights reserved.

 

 

Содержание TBDW100-868

Страница 1: ...Door Window Sensor Reference Manual TBDW100 915 TBDW100 868 ...

Страница 2: ...code 7 6 1 6 Model Name 7 6 2 PE Bag Back Label Label Barcode 7 7 Important Product Safety Instructions 8 8 Warnings 9 9 Notices 10 10 Cautions 10 11 Regulatory 11 1 Description The Door Window sensor utilizes LoRaWAN connectivity to communicate the proximity or not of a magnet The intended use is to place the sensor and magnet on separate elements of a door or window to determine if the door or w...

Страница 3: ...8MHz for North America Tx Power US 19dBm EU 17dBm Rx Sensitivity 135dBm Antenna Gain 2dBi Peak 5dBi Avg 2 4 Certifications and Conformity FCC ID 2AMUGTBSP100 IC 22980 TBSP100 CE ROHS REACH 2 5 Power Source 3 6V 1 2 AA Li SOCl2 1200mAh battery Maximum Voltage 3 6V Minimum Voltage 3 1V Current 135mA maximum 100uA minimum 2 6 User Interface LEDs One blue LED Sensors Hall Effect 14 Gauss trigger typic...

Страница 4: ...there is a transition from Open to Close or vice versa Additionally the device will send a message when it has been inactive for 6 hours 4 Messages LoRaWAN Packets for this device use port 100 4 1 Status 4 1 1 Triggers Packet Triggers 360 minutes inactivity Switch Open Switch Close 4 1 2 Payload Port 100 Payload Length 8 bytes Bytes 0 1 2 3 4 5 6 7 Field Status Battery Temp PCB Time Count 2019 Bro...

Страница 5: ...e 0 127 temperature in C τ 32 RFU measurement range 32 to 95 C Time Time elapsed since the last event triggered Bits 15 0 unsigned value in minutes range 0 65 535 Note little endian format Count Total count of event triggered Bits 23 0 unsigned value range 0 16 777 215 Note little endian format Note This value is not stored persistently on the device and may reset whenever the device is power cycl...

Страница 6: ...ry or battery pack subjected to extremely low air pressure may also result in an EXPLOSION or leakage of flammable liquid or gas Discard used batteries according to the manufacturer s instructions CAUTION The unit is provided with a battery powered circuit There is a danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufact...

Страница 7: ...ers long 6 1 2 JoinEUI 900MHz 58A0CB0000210000 US AU AS923 BR 800MHz 58A0CB0001500000 EU IN RU Uses a hexadecimal representation resulting in 16 characters 6 1 3 DevEUI 58A0CBFFFFFEFFFF Uses a hexadecimal representation resulting in 16 characters 6 1 4 Model number Non reserved characters except and space with a maximum length of 20 characters 2019 Browan Communications Inc All rights reserved 6 ...

Страница 8: ... Label Barcode PE Bag Label Back Label Definition of Back Label and PE Bag Barcode Label GS1 DataMatrix The GS1 Application Identifier 21 indicates that the GS1 Application Identifier data field contains a serial number The GS1 Application Identifier 92 assigned to the company s internal information is DevEUI 2019 Browan Communications Inc All rights reserved 7 ...

Страница 9: ...ld Do not allow children or pets to play with products Observe proper precautions when handling batteries Batteries may leak or explode if improperly handled Observe the following precautions to avoid a sensor explosion or fire Do not drop disassemble open crush bend deform puncture shred microwave incinerate or paint the sensors Hub or other hardware Do not insert foreign objects into any opening...

Страница 10: ...ery leaking do not allow the liquid to come in contact with the skin or eyes If contact has been made wash the affected area with copious amounts of water and seek medical advice Do not use any charger other than that specifically provided for use with the equipment Observe the plus and minus marks on the battery and equipment and ensure correct use Do not use any which is not designed for use wit...

Страница 11: ...oducts Do not use detergent or abrasive materials to clean the Tabs products as this may damage the sensors 10 Cautions CAUTION Disposal of a battery or battery pack into a fire or a hot oven or mechanically crushing or cutting of a battery or battery pack can result in an EXPLOSION Leaving a battery or battery pack in an extremely high temperature surrounding environment that can result in an EXP...

Страница 12: ...n For the full FCC IC Compliance Statements and EU declaration of conformity visit www browan com Contact This symbol means that according to local laws and regulations your product should be disposed of separately from household waste When this product reaches its end of life take it to a collection point designated by local authorities Some collection points accept products for free The separate...

Отзывы: