Z-8550A, 8560A
3. FUNCTION SETTINGS
14
3-3. Data initialization
Initialization of memory data refers to returning all operation panel setting data (including data that has been set using
memory switches) to the factory default settings.
3-3-1. Resetting the settings to their defaults
<Initialization of all setting data>
1
While holding down the RESET key on the operation panel, turn on the power switch (1).
2
The operation panel settings will be returned to their factory
defaults.
After this, operation panel and treadle operation will be
possible.
<Initialization of speed data only>
1
While holding down the MAX key on the operation panel, turn on the power switch (1).
2
The speed data will be set to the speed data for the
machine head detection unit.
After this, operation panel and treadle operation will be
possible.