III - 34
[ 7 ] Attaching the Sensor Cover C, T Sensor PCB ASSY, and Sensor Holder B
(1) Attach the sensor cover C to the sensor holder B.
(2) Attach the T sensor PCB ASSY to the sensor holder B using two double face
tapes TD2000.
(3) Insert the T sensor PCB ASSY harness into the hole on the roll cover inner. Set
the sensor holder B to the roll cover inner, and secure it with the two taptite bind
B M2.6X8 screws.
Figure 3.5-9
Sensor cover C
Sensor holder B
Roll cover inner
T sensor
PCB ASSY
T sensor PCB ASSY
Hole
Taptite bind B M2.6X8
Double face tapes
TD2000