S-7200C
8. USING THE G10 OPERATION PANEL (ADVANCED OPERATIONS)
34
8. USING THE G10 OPERATION PANEL
(ADVANCED OPERATIONS)
The operations described in this section should only be carried out by a technician.
8-1. Changing the needle stop position
This sets whether the needle bar stops in the needle up stop position or the needle down stop position when the treadle is
returned to the neutral position and sewing stops.
* This setting cannot be carried out if the lock function is on. (For details on turning the lock function off, refer to “8-7.
Lock function”.)
1
Activating setting mode
(While pressing the end backtack key, press the power ON switch.)
2
Setting the needle up stop and needle down stop positions
・
When the key is pressed, the “UP”
display will appear.
・
When the key is pressed, the “dn”
display will appear.
…
Needle up stop
…
Needle down stop
NOTE:
If the start backtack key (1) is pressed once
more, the start backtack indicator will switch
off and the display will return to the setting
item.
3
The setting will be stored and the display will
return to the setting item.
4
Setting mode will be exited and normal operation will be possible.
(Setting item)
(Setting item)
(Setting value)
4203M
4204M 2138M 2139M
4205M
4206M