11
(2) Push the cover sensor arms L & R and media sensors, and check that the message
in the “Results” column is changed to “on” or “off”. (Refer to Fig. 12.)
After checking each sensor, “Undo” in the “Results” column is changed to “Done”.
(3) Check all sensors and click the “Quit sensors check” button if the check results are
normal. If not, click the “Sensor test NG” button. Then, finish the inspection.
Fig. 12 Screen when checking the cover sensors and media sensors
Cover sensor arm R
(Cover sensor 0)
Cover sensor arm L
(Cover sensor 1)
Media sensor ASSY
(Media sensor 0~5)
Media sensor ASSY
Click if the sensors are normal.
Click if any of the sensors
does not work correctly.
“on” or “off” is displayed
according to the sensor condition.
“Undo” is changed to “Done” after checking each sensor.