III - 40
3.13 AD Check Mode 2 ([9] key):
Required on the Production Line
Be sure to provide power supply of 9.0 ±0.1V [Insert resistant 1
Ω
±5% (2W and more)]
for the inspection from AA battery.
Connect the adapter and battery fixture at the same time, and press the
[9]
key to
display <
>.
Check if the input power supply voltage and temperature are detected correctly.
Output the "H" of P79 (BAT_AD_ON/OFF) at 500 msec before AD check.
Figure 3.13-1
The LCD displays the power supply voltage and temperature in hex notation by
pressing the key below (see <
>).
The LCD also displays "O" or "X" as a judgment according to the result value.
For European/North American models:
[OK]
or
[ENTER]
Proceed to the display of VAD1 or VAD2 by pressing the
[OK]
or
[ENTER]
key.
Acceptable range:
HTEMP (HEAD_TEMP): 10ºC to 40ºC (A5H to 5EH)
PTEMP (PCB_TEMP): 10ºC to 50ºC (A6H to 47H)
VAD (VBT_VOLTAGE): Specified power supply voltage 7.0V to 9.5V (5DH to 8AH)
Figure 3.13-2
For European/North American models, the display returns to as shown in <
> by pressing the
[OK]
or
[ENTER]
key.
AD CHECK START
HTMP
PTMP
VAD
7F O
7F O
7E O
<Example>
(Power supply voltage:
about 9.0V at 25ºC)