[ 3 ] Powering failure (Nothing appears on the LCD.)
N
Y
Y
Y
Y
N
N
Y
N
Are the
specified batteries
loaded? (alkaline batteries
LR6/Ni-HM batteries
HR6)
Replace them
with the specified
ones.
Are the
batteries loaded with
right polarity?
Correct the
loading direction.
Is the specified
AC adapter
*
connected?
Replace it with
the specified one.
* AD-E001
When driven by batteries:
When driven via the
AC adapter*:
Pressing the key does not turn
the machine on; nothing appears
on the LCD.
Replace the batteries with
new ones.
Load batteries or connect
the specified adapter, and
press the On/Off key.
Replace the LCD.
Remove batteries, disconnect
the specified AC adapter (if
connected), and hold down
the On/Off key for at least 10
seconds to discharge the
internal capacitor.
Power supplied?
End of repair.