2-46
Confidential
Error code A1
The front cover sensor detected that the front cover was open.
Error code A2
The document scanning position sensor detected that the document length was 90 cm or
more while scanning the document.
Cover is Open
Close the Front Cover.
<User Check>
• Check that the front cover is closed correctly.
Step
Cause
Remedy
1
Connection failure of the high
voltage power supply PCB
ASSY harness (Front cover
sensor is mounted in high
voltage power supply PCB
ASSY.)
Reconnect the high voltage power supply PCB
ASSY harness.
2
Part pressing the front cover
sensor is broken, which is
provided at inside of front cover
Replace the front cover ASSY.
3
Front cover sensor failure
Check the performance of the front cover
sensor following the procedure in
. If any problem occurs, replace the
high voltage power supply PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Document Jam
Clear the scanner jam, then press the Stop Key.
<User Check>
• Check that the document or the foreign object is not jammed in the ADF. If jammed,
remove it.
Step
Cause
Remedy
1
Document scanning position
actuator catching on some
position
Correct the position of the document scanning
position actuator.
2
Document scanning position
sensor failure
Replace the panel PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Содержание FAX-2950
Страница 20: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 35: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Страница 45: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Страница 122: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 130: ...3 6 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Страница 136: ...3 12 Confidential 3 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Страница 140: ...3 16 Confidential 8 Main fan High voltage power supply PCB ASSY Guide Main fan Tape Hole of guide Hole of guide ...
Страница 143: ...3 19 Confidential 12 Speaker unit Guide Speaker harness Guide Guides Guides Speaker unit Main PCB ASSY ...
Страница 153: ...3 29 Confidential 9 3 Cord hook 1 Turn the two cord hooks and then remove them from the machine Fig 3 12 Cord hooks ...
Страница 204: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 217: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 224: ...5 5 Confidential Black and white color scanning Fig 5 1 ...
Страница 263: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Страница 266: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 267: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Страница 268: ...7 1 Confidential 1 PERIODICAL REPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 269: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 273: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...
Страница 275: ...Confidential APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL FOR DRUM UNIT ...