App. 4-52
Confidential
WSW50
(SDAA settings)
Selector
No.
Function
Setting and Specifications
1
2
Percentage voltage for
interpreting the external
telephone as being hooked up
(based on the network's standard
voltage)
No. 1 2
0 0 : 80%
0 1 : 90%
1 0 : 70%
1 1 : No detection
3
DC mask curve table to be
applied when the line is
connected
0:
Apply the initial value specified by local
regulations
1:
Apply table DC5 prepared specially
4
AC impedance to be applied
when the line is connected
0:
600
W
termination
1:
ZR termination
5
6
Current control to be applied
immediately after connection
of the line
No. 5 6
0 0 : Standard
0 1 : Increase start-up current for
termination
1 0 : Fine current control for termination
1 1 : Not used. (equal to "0, 0")
7
8
AC voltage threshold for
detection of ring
No. 7 8
0 0 : 19 V
0 1 : 11 V
1 0 : 25 V
1 1 : 31 V
NOTE:
WSW50 is applicable to models equipped with SDAA circuits.
l
Selectors 5 and 6: Current control to be applied immediately after connection of the line
FAX models equipped with an SDAA circuit (on which an NTU chip is mounted) might not be
connected to a broad band line such as an ADSL (Asynchronous Digital Subscriber Line) in a stable
condition. If those models fail to connect to such a line, try to change the current control to be
applied immediately after connection of the line by using selectors 5 and 6.
If selectors 5 and 6 are set to "0" and "1," respectively, the SDAA draws more current, decreasing
the period required to terminate the current control. If they are set to "1" and "0," the SDAA finely
controls precision of the termination current against the voltage to approach nearer to the specified
DC curve that specifies the current vs. voltage characteristics of the network termination. Selecting
either control may solve an unstable connection problem.
Содержание FAX 1840C
Страница 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC3340CN 3240C FAX1940CN 1840C 1835C ...
Страница 9: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Страница 18: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Страница 50: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Страница 91: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Страница 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 140: ...5 42 Confidential n Reassembling Notes Route the battery harness beneath the ink supply tubes as shown below ...
Страница 167: ...5 69 Confidential Viewed from the left ...
Страница 171: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 189: ...6 16 Confidential Paper Feeding Check Patterns for the Paper Feed Roller and Paper Ejection Roller A Þ B Þ ...
Страница 191: ...6 18 Confidential Vertical Alignment Check Patterns ...
Страница 193: ...6 20 Confidential Margin Check Pattern ...
Страница 202: ...Confidential CHAPTER 7 CLEANING ...
Страница 205: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Страница 213: ...8 6 Confidential FAX1940CN 1840C 1835C Black Start Mono Start key Stop Exit key Menu Set key and keys ...
Страница 216: ...8 9 Confidential Scanning Compensation Data List a b c d e f i ...
Страница 233: ...8 26 Confidential Paper Feeding Check Pattern for the Paper Feed Roller and Paper Ejection Roller A Þ B Þ ...
Страница 236: ...8 29 Confidential 1st sheet 2nd sheet Vertical Alignment Check Patterns ...
Страница 239: ...8 32 Confidential Margin Check Pattern ...
Страница 249: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 253: ...9 2 Confidential ...
Страница 254: ...9 3 Confidential ...
Страница 371: ...B Power Supply PCB U S A and Canadian models Confidential ...
Страница 372: ...B Power Supply PCB European and Asian models Confidential ...
Страница 401: ...Confidential February 05 SM FAX032 8XA901 5 Printed in Japan ...