Faint print
■
White spots
User Check
• Check that the machine is installed on a level surface.
• Replace the toner cartridge with a new one.
• Clean the scanner windows of the laser unit with a soft
cloth. (
Refer to Fig. 1-6.
)
Step
Cause
Check
Result
Remedy
1
Main PCB failure
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
2
Laser unit failure
Is the problem solved
after replacing the laser
unit?
Yes
Replace the laser unit.
3
Toner empty
sensor failure
Is the "Toner Life End"
message indicated on
the LCD after replacing
the current toner
cartridge with the empty
toner cartridge?
No
Replace the toner sensor
PCB ASSY.
User Check
• Toner may be empty. Replace the toner cartridge with a new one.
• If the problem is not solved after printing a few pages, the drum unit
may have glue from label stuck on the exposure drum surface. Refer
to the
, and wipe it off gently with a cotton swab.
• The drum unit may be damaged. Replace the drum unit with a new
one.
Step
Cause
Check
Result
Remedy
1
Toner attached
on the develop
roller
Are the white spots at
40.6 mm (develop roller
circumference)
intervals?
Yes
This problem will
disappear by printing
approximate 10 pages. If
the same problem occurs,
replace the toner cartridge.
2
Scratch and Dirt
on the exposure
drum
Are the white spots at
75.0 mm (exposure
drum circumference)
intervals?
Yes
Replace the drum unit.
3
Drum unit
connection
failure
Are the electrodes on
the drum unit and
machine body dirty?
Yes
Clean both electrodes.
(Refer to
).
4
HVPS PCB
failure
Is the problem solved
after replacing the
HVPS PCB ASSY?
Yes
Replace the HVPS PCB
ASSY.
5
Main PCB failure
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
Содержание DCP-7030
Страница 78: ...2 2 Confidential 2 PERIODICAL PEPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 133: ...3 55 Confidential 8 12 8 ADDRESS LABEL 1 Remove the Address label from the Panel unit Fig 3 53 Address label Panel unit ...
Страница 150: ...3 72 Confidential 8 27 FILTER ASSY 1 Remove the Filter ASSY from the Main body Fig 3 72 Filter ASSY Front side ...
Страница 178: ...3 100 Confidential 8 39 RUBBER FOOT 1 Remove the two Rubber feet from the Main body Fig 3 104 Rubber foot Front side ...
Страница 201: ...5 5 Confidential Print sample Fig 5 1 ...
Страница 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Страница 233: ...6 1 Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM High voltage Power Supply PCB Circuit Diagram ...
Страница 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Страница 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Страница 239: ...6 7 Confidential Wiring Diagram ...