1-30
Confidential
5.3
Troubleshooting Image Defect
Image defect related problems are end user recoverable if following the User Check items. If
the same problem occurs, follow each procedure in the order of the number described in the
Step column in the tables below.
■
Light
User Check
• Check the machine's environment. Low temperature and low
humidity conditions can cause this problem.
• If the whole page is light, toner save mode may be on.
• Replace the toner cartridge or drum unit with a new one.
Step
Cause
Check
Result
Remedy
1
Dirt on exposure
drum electrode
Are the electrodes of the
drum unit and machine
body dirty?
Yes
Clean both electrodes.
(
)
2
Dirt on scanner
windows of the
laser unit
Is the scanner windows
of the laser unit dirty?
Yes
Wipe the dirt off with a soft,
clean, lint free cloth.
(
Refer to Fig. 1-6.
)
3
Toner sensor
failure
After replacing the toner
cartridge with a new
one, does the same
problem occur even
after printing several
pages?
Yes
Replace the toner
cartridge.
4
Does the machine start
printing even after
removing the toner
cartridge from the drum
unit?
Yes
Clean the toner sensor.
(receiving light side)
Check the harness
connection of the toner
LED PCB ASSY.
(luminescence side)
Replace the toner sensor
PCB ASSY or toner LED
PCB ASSY.
5
Between the
HVPS PCB/Main
PCB connection
failure
Is the harness of the
HVPS PCB ASSY and
main PCB ASSY
connected correctly?
No
Reconnect the harness of
the HVPS PCB ASSY and
main PCB ASSY.
6
HVPS PCB
failure
Is the problem solved
after replacing the
HVPS PCB ASSY?
Yes
Replace the HVPS PCB
ASSY.
7
Main PCB failure
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
8
Laser unit failure
Is the problem solved
after replacing the laser
unit?
Yes
Replace the laser unit.
Содержание DCP-7030
Страница 78: ...2 2 Confidential 2 PERIODICAL PEPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 133: ...3 55 Confidential 8 12 8 ADDRESS LABEL 1 Remove the Address label from the Panel unit Fig 3 53 Address label Panel unit ...
Страница 150: ...3 72 Confidential 8 27 FILTER ASSY 1 Remove the Filter ASSY from the Main body Fig 3 72 Filter ASSY Front side ...
Страница 178: ...3 100 Confidential 8 39 RUBBER FOOT 1 Remove the two Rubber feet from the Main body Fig 3 104 Rubber foot Front side ...
Страница 201: ...5 5 Confidential Print sample Fig 5 1 ...
Страница 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Страница 233: ...6 1 Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM High voltage Power Supply PCB Circuit Diagram ...
Страница 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Страница 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Страница 239: ...6 7 Confidential Wiring Diagram ...