3-95
Confidential
8.37.2 T1 SOLENOID
(1) Remove the T1 solenoid lever spring from the Main body and the T1 solenoid lever.
(2) Remove the Harness from the Guide part of the Main body.
(3) Remove the Taptite bind B M3x10 screw, and then remove the T1 solenoid from the
Main body.
(4) Remove the T1 solenoid lever from the T1 solenoid.
Fig. 3-99
T1 solenoid lever
T1 solenoid lever spring
T1 solenoid
Hook
Taptite bind B M3x10
Harness
Guide part
1
3
3
4
2
<Left side>
Содержание DCP-7030
Страница 78: ...2 2 Confidential 2 PERIODICAL PEPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 133: ...3 55 Confidential 8 12 8 ADDRESS LABEL 1 Remove the Address label from the Panel unit Fig 3 53 Address label Panel unit ...
Страница 150: ...3 72 Confidential 8 27 FILTER ASSY 1 Remove the Filter ASSY from the Main body Fig 3 72 Filter ASSY Front side ...
Страница 178: ...3 100 Confidential 8 39 RUBBER FOOT 1 Remove the two Rubber feet from the Main body Fig 3 104 Rubber foot Front side ...
Страница 201: ...5 5 Confidential Print sample Fig 5 1 ...
Страница 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Страница 233: ...6 1 Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM High voltage Power Supply PCB Circuit Diagram ...
Страница 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Страница 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Страница 239: ...6 7 Confidential Wiring Diagram ...