App.
4-18
Confidential
WSW14
(AUTO ANS facility setting)
Selector
No.
Function
Setting and Specifications
1
2
Frequency band selection (lower
limit) for incoming calling signal
(CI)
No. 1 2
0 0 : 13
Hz
0 1 : 15
Hz
1 0 : 23
Hz
1 1 : 20
Hz
3
4
Frequency band selection (upper
limit) for incoming calling signal
(CI)
No. 3 4
0 0 : 30
Hz
0 1 : 55
Hz
1 0 : 70
Hz
1 1 : 200
Hz
5
|
8
No. of rings in AUTO ANS mode
No. 5 6 7 8
0 0 0 0 : Fixed
to
once
0 0 0 1 : Fixed
to
2
times
0 0 1 0 : Fixed
to
3
times
0 0 1 1 : Fixed
to
4
times
0 1 0 0 : 1
to
2
times
0 1 0 1 : 1
to
3
times
0 1 1 0 : 1
to
4
times
0 1 1 1 : 1
to
5
times
1 0 0 0 : 2
to
3
times
1 0 0 1 : 2
to
4
times
1 0 1 0 : 2
to
5
times
1 0 1 1 : 2
to
6
times
1 1 0 0 : 1
to
10
times
1 1 0 1 : 2
to
10
times
1 1 1 0 : 3
to
5
times
1 1 1 1 : 4
to
10
times
Selectors 1 through 4: Frequency band selection for incoming calling signal (CI)
These selectors are used to select the frequency band of CI for activating the AUTO ANS facility.
In the French models, if the user sets the PBX to OFF from the control panel, the setting made by
selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even
if the setting made by these selectors does not apply, it will be printed on the configuration list.)
Selectors 5 through 8: No. of rings in AUTO ANS mode
These selectors set the number of rings to initiate the AUTO ANS facility.
Содержание DCP-7010
Страница 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC7420 7820N DCP7010 7020 7025 ...
Страница 14: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Страница 20: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Страница 44: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Страница 64: ......
Страница 65: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Страница 68: ...Confidential 4 2 Cover page sample End page sample ...
Страница 69: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 150: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 154: ...Confidential CHAPTER 7 CLEANING ...
Страница 156: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Страница 164: ...8 7 Confidential Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Страница 172: ...8 15 Confidential Configuration List ...
Страница 178: ...8 21 Confidential Cover page sample End page sample ...
Страница 187: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 321: ...A NCU PCB MFC7420 U S A and CANADA models Confidential ...
Страница 322: ...A NCU PCB MFC7820N U S A and CANADA models Confidential ...
Страница 323: ...A NCU PCB MFC7420 EUROPE models Confidential ...
Страница 324: ...A NCU PCB MFC7820N EUROPE models Confidential ...
Страница 325: ...B Power Supply PCB 100V U S A and CANADA models Confidential ...
Страница 326: ...B Power Supply PCB 200V EUROPE models Confidential ...
Страница 327: ...December 04 SM FAX036 2 8C5A03 Printed in Japan ...