8. LIST OF ERROR CODES
BAS-326H-484, BAS-326H-484 SF
54
Board-related errors
Code
Cause of error and remedy
E700
Abnormal rise in power supply voltage.
Turn off the power, and then check the input voltage.
E701
Abnormal rise in main motor drive voltage.
Turn off the power, and then check the voltage.
E705
Abnormal drop in power supply voltage.
Turn off the power, and then check the input voltage.
E710
Abnormal current was detected in main motor.
Turn off the power, and then check if there are any problems with the sewing machine.
Turn off the power, and then check that connectors P11 and P1 on the motor board, P6 on the main board and
P4 of the main motor are properly inserted.
E711
Abnormal current was detected in pulse motor.
Turn off the power, and then check if there are any problems with the work clamp operation.
E730
External error input (AIRSW) was detected.
Turn off the power, and then check the air pressure.
Version updating-related errors
Code
Cause of error and remedy
E860
No main software is present.
Install the main control software.
E865
No motor software is present.
Install the motor control software.
E880
Software update request is not accepted.
Turn off the power, and then turn it back on again.
E881
Software updating did not complete normally.
Turn off the power, and then repeat the software update procedure.
E883
No software data is present in the storage media.
Check that the software data has been saved into the correct folder.
E884
There is a problem with the software data.
Write the correct data into the storage media.
E887
Software updating could not be carried out. Turn off the power, and then turn it back on again.
E888
It failed to send and receive software update file.
Please try again.
E889
Written data to flash memory is incorrect.
Please try again.
E890
Software updating could not be carried out.
Please try again.
Other errors
Code
Cause of error and remedy
E920
Failed to read bar-code. Press the RESET key to clear the error.
If an error code that is not listed above appears or if carrying out the specified remedy does not solve the problem,
contact the place of purchase.