2. FUNCTION SETTINGS
7
BAS-311G, BAS-326G
No.
Setting
range
Setting items
Initial value
Work clamp operation before home position detection
OFF
Work clamp cannot be raised or lowered before home position is detected
051
ON
Work clamp can be raised and lowered before home position is detected
ON
Work clamp operation during split programs
OFF
Work clamp lifts automatically when sewing pauses due to a split program
052
ON
Work clamp lifts when the foot switch is depressed when sewing pauses due to a
split program
OFF
Time from intermittent presser foot lifting until feed mechanism starts moving
053
0
−
999
Units (mS)
100
Intermittent presser foot drop timing
0
Presser foot drops when the work clamp switch is depressed, but it does not drop
at the feed retract position.
1
Presser foot drops when the work clamp switch is depressed.
054
2
Presser foot drops at the sewing start, regardless of the work clamp switch
operation.
0
Work clamp signal valve special output for pneumatic-type work clamp (pneumatic specifications)
0 Disabled
1
Valve output is reversed for pneumatic specifications
(Connect the air tubes in reverse so that the work clamp can lift when the power is
turned off.)
055
2
Reverse valve output is output simultaneously for 2-position valve specifications.
(Right work clamp reverse = Option output No. 4, Left work clamp reverse =
Option output No. 5)
0
Thread winding operation before home position is detected
OFF
Thread winding cannot be carried out before home position is detected.
056
ON
Thread winding can be carried out before home position is detected.
OFF
Work clamp operation when feed moves to sewing start position after home position is detected
OFF
Work clamp stays dropped after home position is detected
Work clamp lifts when pedal is depressed backward (for single pedal) or when
work clamp switch is depressed (for 2 pedals)
057
ON
Work clamp lifts automatically after home position is detected.
* Disabled when memory switch No. 050 = 2 or 4.
ON
Work clamp operation at sewing end
OFF
Work clamp lifts automatically at the sewing end
* Disabled when memory switch No. 050 = 2 or 4.
058
ON
Work clamp does not lift automatically at the sewing end
OFF
Содержание BAS-311G
Страница 121: ...8 ELECTRICAL MECHANISM 114 BAS 311G BAS 326G PMD P C board Power supply motor P C board 4592Q 4593Q ...
Страница 122: ...8 ELECTRICAL MECHANISM 115 BAS 311G BAS 326G Panel P C board 4594Q ...
Страница 127: ...8 ELECTRICAL MECHANISM 120 BAS 311G BAS 326G 5251Q ...
Страница 128: ...8 ELECTRICAL MECHANISM 121 BAS 311G BAS 326G 5252Q ...
Страница 129: ...8 ELECTRICAL MECHANISM 122 BAS 311G BAS 326G 5253Q ...