Broseley WINCHESTER Скачать руководство пользователя страница 1

200707_3 

  
 
 

 

 
 
 

Installation & Operating Instructions 

 
 

Model: Winchester 

Conventionally Flued Natural Gas Stove

  

 
 
 
 

 
 

 

 

 
 
 
 
 

 

 

 

 
 
 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

 

 

Broseley Fires do not provide flue pipes, closure plates or any other 

associated accessory. 

 

Please note gas installations MUST only be carried out by installers who 

are Gas Safe registered. 

 

Warning

 - Appliance should not be used if the glass in the door is 

cracked, damaged or broken. 

Содержание WINCHESTER

Страница 1: ...E THESE INSTRUCTIONS WITH THE USER Broseley Fires do not provide flue pipes closure plates or any other associated accessory Please note gas installations MUST only be carried out by installers who ar...

Страница 2: ...tallation 7 Connecting the TTB sensor 8 Positioning the Coal Ceramics 9 Positioning the Log Ceramics 12 Gas Connection Pressure Testing 13 Spillage Testing 14 Operating the Stove 15 The Remote Control...

Страница 3: ...d accredited gas fitter listed on the Gas Safe register Please Note THE INSTALLATION MUST BE CARRIED OUT BY A GAS SAFE REGISTERED ENGINEER IN ACCORDANCE WITH THE GAS SAFETY INSTALLATION AND USE REGULA...

Страница 4: ...6 6 kW hr Max Heat Ouput 5 5 kW hr Supply Pressure 20 mbar Gas Rate 0 611 m3 Hr Injector Size 460 Spigot diameter 125mm 5 Weight 116 Kg Please note this product is designed to only use natural gas Dim...

Страница 5: ...Rear Non Combustible 75mm Side Combustible 610mm Non Combustible 100mm Hearth Protrusion in front of the appliance 50mm Shelf Distance combustible material 610mm Please note these are minimum clearanc...

Страница 6: ...eally it is recommended that the flue run is as straight as possible using the top outlet on the stove When using the rear outlet if alignment of the top outlet is not possible a T shaped flue section...

Страница 7: ...hat the L brackets line uo with the screw holes in the internal rear plate 3 Next with the stove stood upright insert the burner control first through the door Dip the controls through the bottom of t...

Страница 8: ...burner installed thread the TTB connection cable from the interrupter to the TTB sensor mounted on the rear panel of the stove TTB sensor located just below the rear flue outlet Thermo Couple To Gas...

Страница 9: ...so always handle with care when fitting them Follow these instructions carefully Ceramics that are positioned wrongly could seriously alter the performance of your appliance Step 1 Open the door fully...

Страница 10: ...via the location holes and lugs Ensure the flat rear side of the ceramics is against the back of the stove Step 3 Take the smaller of the rear ceramics right hand side and locate it into position on...

Страница 11: ...the flames from burning evenly and effectively The path of the flame should not be obstructed Finally close the stove door and wind on the M6 x 18 hex bolt back onto the door fixing bolt slide the ha...

Страница 12: ...age Two Stage Three Position the rear log onto the two location Position the next log as shown in lugs towards the rear of the base ceramic the diagram below This log also as shown in the diagram Has...

Страница 13: ...lways make sure that there is adequate gas pressure and volume to the stove The relevant pressures are on the ID plate on the gas control knob 1 For natural gas this is 20mbar measured at the burner t...

Страница 14: ...ed the device will recognise the fault as an increase in heat inside the stove and shut the appliance down within a safe period so that there is no excessive build up of products of combustion inside...

Страница 15: ...hear a click Repeat until the pilot lights 3 Keep knob depressed at this point for 15 20 seconds 4 Upon releasing turn the knob anti clockwise until it stops in the permanent pilot light position The...

Страница 16: ...the and buttons After fitting the batteries and replacing the cover the fire can now operate Slide the power isolator switch to the right to the on I position To start the fire press the power button...

Страница 17: ...e rear of both sides of the button area control The green unlock light will illuminate Keep the handset held to keep the control unlocked to enable operation of the buttons Then with the other hand to...

Страница 18: ...und the rear of both sides of the button area control The green unlock light will illuminate Keep the handset held to keep the control unlocked i e the green light on at all times to enable operation...

Страница 19: ...es back to the previous parameter and change the display parameter Setting the display for 12 or 24 Hour display The H indicates that it is time to set the timer to either 24 hour display or 12 Hour A...

Страница 20: ...egend at the bottom shows the battery condition of both the batteries in the hand set and in the fire control alternately RC Remote Control handset and FC Fire control The control is designed to get t...

Страница 21: ...n initial installation Check understanding of control operation is understood If either the handset is reset or the gas control has the pairing operation buttons operated the pairing that existed will...

Страница 22: ...s N B If the display returns to the one shown above with the word TESC shown then too much time has passed before pressing SET and so the handset has not paired yet Simply repeat pairing again N B Onl...

Страница 23: ...showing this set temperature press the and buttons to alter the setting When finished either press set or leave and after a few seconds the new setting will be accepted and the display will return to...

Страница 24: ...e in the weather The control must be left in the appropriate mode for this to function Note As stated in an earlier section snooze function can also be operated in conjunction with thermostat mode The...

Страница 25: ...is installed by a qualified and accredited GAS SAFE installation engineer Improper installation adjustment alteration service or maintenance can cause personal injury and or damage to property If you...

Страница 26: ...ing sound you hear is normally caused by dirt obstructing the pilot This is normally cured by carrying out the cleaning process outlined in the next section entitled Servicing Instructions After alter...

Страница 27: ...ut a soft brush will do Check the condition of the coals Any damaged ones will affect the efficient operation of the stove and should be replaced with new ones available from your stove supplier All g...

Страница 28: ...cessive __________ Is there any permanent ventilation in the room ____________________ Has the room double glazing ______________ Is the aeration of the pilot correct __________ Does the flame encircl...

Страница 29: ...YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 5TH YEAR SERV...

Страница 30: ...ance with our instructions or Repairs or modifications have been carried out by the purchaser or any third party not authorised by us or The appliance has been misused or accidentally damaged or Damag...

Страница 31: ...Floor Unit B Knights Court Archers Way Battlefield Enterprise Park Shrewsbury Shropshire SY1 3GA Product Fiche Manufacturer Broseley Fires Ltd Model No Winchester Gas Stove Top Flue Winchester Gas Sto...