Installation
Installation Procedure
3. Installation
1. Select a location complying with the advice in Section 2.
2. Remove the mounting plate from the Smoke/Heat Alarm by twisting it in an
anti-clockwise direction (see Figure 5).
3. Place the mounting plate on the ceiling exactly where you want to mount the
Alarm. With a pencil, mark the location of the two screw holes.
4. If interconnecting Alarms using
hard-wired connections, run suitable
twin core cabling to the marked locations
of each Alarm. Make the connections to
the Alarm (see Section 4).
5. Taking care to avoid any electrical
wiring in the ceiling, drill holes using
a 5.0mm drill bit through the centre of
the marked locations. Push the plastic
screw anchors provided into the drilled
holes. Screw the mounting plate to the
ceiling.
If using RadioLINK Smoke/Heat Alarms
then they should be mounted with
antennas in the same orientation (i.e.
essentially parallel). This means picking
13
ROTATE UNIT ANIT-CLOCKWISE
UNIT WILL NOT TWIST OFF - IT MAY BE
TAMPERPROOFED - SEE FIGURE 8c
Figure 5