background image

4

bromic.com/heat

IMPORTANT NOTES AND WARNINGS

WARNING

• THIS APPLIANCE SHALL NOT BE INSTALLED OR USED 

  IN RESIDENTIAL DOMESTIC INDOOR AREAS
•  CHILDREN AND ADULTS SHOULD BE ALERTED TO THE
  HAZARDS OF HIGH SURFACE TEMPERATURES AND
  SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING
 IGNITION
•  YOUNG CHILDREN SHOULD BE CAREFULLY
  SUPERVISED WHEN THEY ARE IN THE AREA OF THE
 HEATER
•  DO NOT USE OR STORE FLAMMABLE MATERIALS
  NEAR THIS APPLIANCE
•  CLOTHING OR FLAMMABLE MATERIALS SHOULD NOT
  BE HUNG FROM THE HEATER OR PLACED ON OR
  NEAR THE HEATER
•  DO NOT SPRAY AEROSOLS OR FLAMMABLE MATERIALS
  IN THE VACINITY OF THIS APPLIANCE WHILE IT IS IN
 OPERATION
•  ANY GUARD OR OTHER PROTECTIVE DEVICE
  REMOVED FOR SERVICING THE HEATER (CONDUCTED BY
  AN AUTHORIZED PERSON) MUST BE REPLACED PRIOR TO
  OPERATING THE HEATER
•  INSTALLATION AND REPAIR SHOULD BE DONE BY A
  QUALIFIED SERVICE PERSON. THE HEATER SHOULD
  BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY
  BY A QUALIFIED SERVICE PERSON
Failure to follow the warnings and instructions in this manual 

could result in severe personal injury, death or property damage.

• 

This Installation, Operation and Service manual should not 

be removed from the site of installation.

• 

Installer should leave manual with the customer for future 

reference.

• 

This Appliance is approved FOR OUTDOOR OR AMPLY 

VENTILATED AREA USE. (see attached diagrammatical 

representations of outdoor areas “Appendix A”) and for 

NON DOMESTIC INDOOR APPLICATION.

• 

Do not perform maintenance until heater has been turned 

off, power disconnected, and heater temperature has 

cooled to room temperature.

• 

Do not expose the burner to water or moisture.  

THE APPLIANCE IS TO BE PROTECTED FROM RAIN.

• 

Do not use the heater if any of these parts are exposed 

to water until the appliance is inspected or repaired by an 

authorised service person.

• 

The installer is to ensure that the requirements of the local 

authority, local gas fitting regulations, municipal building 

codes, and any other relevant statutory regulations are 

carried out.

• 

Certain materials or items, when stored under or near the 

appliance, will be subjected to radiant heat and could be 

seriously damaged. Ensure combustible materials eg. 

overhead structures, walls, floors, furniture, fixtures and 

plants must be kept 1100mm from the top and side.

• 

The whole gas system, hose assembly, regulator, pipes, and 

burner should be inspected for damage and leaks before 

use and at least annually by an authorized person for the 

life of the heater.

• 

All leak tests should be done with a soap solution. Never 

use an open flame to check for leaks.

• 

Do not use the heater until all connections have been leak 

tested by an authorised person.

• 

Inspect the hose assembly before each use of the appliance.

• 

The hose assembly must be replaced prior to the appliance 

being put into operation if there is evidence of excessive 

abrasion or wear, or if the hose is damaged.

• 

The replacement hose assembly must be AGA approved.

• 

The hose assembly is not to be located in areas where the 

hose may be subject to accidental damage.

• 

This radiant heater is NOT intended to be installed on 

recreational vehicles and/or boats.

• 

Repair to be carried out ONLY by an authorised person.

• 

Improper installation, adjustment, or alteration can cause 

personal injury, property damage, or even death.

• 

Do not attempt to alter the unit in any manner.

• 

Remove transit protection before use.

• 

Never operate the heater in an explosive environment such 

as areas where petrol or other flammable liquids or vapours 

are stored.

• 

Turn off the gas supply immediately if smell of gas is 

detected.

• 

Do not paint any surface of the heater.

• 

Do not throw objects at Glass facia.

• 

The facia breaks, discontinue use, disconnect power and 

gas and isolate area affected by breakage.

• 

Control compartment, burner and circulation air 

passageways of the heater must be kept clean. Frequent 

cleaning may be required as necessary.

• 

Turn Gas Supply off when not in use.

• 

Check the heater immediately if any of the following occurs:

 

»

The heater does not reach temperature.

 

»

The burner makes popping noise during use (a 

slight noise is normal when the burner is ignited or 

extinguished).

• 

This appliance can be used by children aged from 8 years 

and above and persons with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge if 

they have been given supervision or instruction concerning 

use of the appliance in a safe way and understand the 

hazards involved. Children shall not play with the appliance. 

Cleaning and user maintenance shall not made by children 

without supervision.

• 

Check for damage to the appliance regularly. If damage to 

the cord, plug or appliance is suspected, discontinue use 

immediately and contact the supplier or qualified person 

for repair.

• 

If the supply cord and plug is damaged, It must be replaced 

by the manufacturer, its service agent or similarly qualified 

persons in order to avoid hazard.

• 

Avoid inhaling fumes emitted from the heater’s first 

use. Smoke and odour from the burning of oils used in 

manufacturing will appear. Both the smoke and odour will 

dissipate after approximately 30 minutes.

• 

Ensure that a watertight seal is maintained on the electrical 

control box at all times

• 

Regularly check for damage to the rubber seals. If damage to 

the rubber seals is suspected, discontinue use immediately, 

switch off power and contact the place of purchase or 

authorized service technician for repair.

• 

The heater is not located immediately below a socket outlet

• 

The appliance shall, under no circumstances, be covered 

with insulating material or similar material.

• 

Fire Sprinklers must be located at an appropriate distance 

from each heater to avoid accidental activation of the 

sprinkler. Ethylene glycol or propylene glycol must never be 

used in fire sprinkler systems where heaters are present as 

these substances maybe become flammable when heated. 

A fire sprinkler professional must be consulted when heaters 

are installed where fire sprinklers are present to ensure that 

heaters and the fire sprinkler system are properly integrated.

!

Содержание PLATINUM 300 SMART-HEAT

Страница 1: ...ues keep away from the appliance and immediately call your gas supplier or fire department Do not store or use gasoline or other flamable vapor and liquids in the vicinity of this or any other applian...

Страница 2: ...lled must be electrically grounded in accordance with local codes This appliance is approved FOR OUTDOOR OR AMPLY VENTILATED AREA USE and for NON DOMESTIC INDOOR APPLICATION When installed outdoors th...

Страница 3: ...WER SUPPLY INSTALLATION 13 LEAKAGE TEST 13 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 14 COMMISSIONING INSTRUCTION CHECK GAS PRESSURE 14 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 15 OPERATING INSTRUC...

Страница 4: ...roved The hose assembly is not to be located in areas where the hose may be subject to accidental damage This radiant heater is NOT intended to be installed on recreational vehicles and or boats Repai...

Страница 5: ...ce shall be used on a regulated supply 3 Governor out of action 4 Not designed for field conversion SPECIFICATIONS Table 1 Platinum Smart Heat 500 Gas type G31 PROPANE1 G20 NATURAL GAS2 G25 NATURAL GA...

Страница 6: ...omestic indoor use In addition to the installation instructions provided authorised installers must abide by the local gas installation code Please note that these standards are subject to change The...

Страница 7: ...re than two walls ref Appendix A Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following shall apply At least 25 of the total wall area is complete...

Страница 8: ...300 Series 1100mm 1100mm 2500mm 500 Series 1100mm 1100mm 2500mm following installation clearances shall apply Note When installing with the Platinum Smart Heat C Minimum Mounting Height to Ground B A...

Страница 9: ...inside the centre of the arm and have them exit through the shaped cut out on top surface of the arm Ensure that the arm faces downwards at a 55 angle Position the 4 mounting holes on the arms plate...

Страница 10: ...slide into place TIP Do not install the mounting pin at this point Spray soapy water on the arm to ease the sliding 5 Connect an approved flexible connector to the Gas Valve Outlet Fitting Position he...

Страница 11: ...carefully following the instructions below IMPORTANT Electrical connections must be completed by trained and authorized electrical technicians only PLEASE NOTE THERE IS NO NEED TO REMOVE OR UNPLUG THE...

Страница 12: ...TANT Ensure that a water tight seal is maintained 10 Main Power supply connection is to completed in line with instructions in the Power supply installa tion section of this manual IMPORTANT Children...

Страница 13: ...EAKAGE TEST Gas connections on the heater are leak tested at the factory prior to shipment A complete gas tightness check must be performed at the installation site due to possible mishandling in ship...

Страница 14: ...r pressure test point sealing screw one to two turns on the Honeywell multifunctional control and connect a manometer see photography B1 Turn on the appliance and operate for at least 5 minutes Check...

Страница 15: ...spective of pitched or flat ceiling 1 Mount Top Bracket to ceiling or support beam using suitable fixings no less than 60mm length 2 Assemble pole to the mounting bracket using the M8x100mm and M19x10...

Страница 16: ...s gasoline and other flamable vapors and liquids Do not clean heater with cleaners that are combustible or corrosive REGULAR SERVICE REQUIREMENTS 1 AGA approved Gas Hose located within the mounting ar...

Страница 17: ...le for atmospheric gas burners for non permanent operation Although the Honeywell unit is available non volatile lockout its configuration in the Platinum Smart Heat series heaters limits it to volati...

Страница 18: ...me is detected during the safety time the ignition device is inhibited and the gas valve remains energised If the control does not detect any flame signal during the safety time at the end of safety t...

Страница 19: ...ed 230 V Blue Purple Purple ELECTRICAL DIAGRAM SEE INSTRUCTION MANUAL FOR DETAILS ON HOW TO CONNECT THE ELECTRICAL COMPONENTS Note If any of the original wire as supplied with the heater must be repla...

Страница 20: ...20 bromic com heat REPLACEMENT PARTS 8 13 16 7 1 2 1 4 5 6 9 11 15 27 14 26 12 25 20 17 18 24 Honeywell...

Страница 21: ...ing Mount Bottom 12 Rear Cover Assembly BH8080026 BH8080027 13 Rear Cover Mount 14 Burner BH8080030 BH8080030 15 Wiring Harness Ignitor Assembly BH8080010 BH8080011 16 Inner Skin BH8080028 BH8080029 1...

Страница 22: ...Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s installation location pose a hazard to the site Yes No Do heater clearances match the minimu...

Страница 23: ...matter in venturi tube 1 Adjust valve regulator until 1kpa for natural gas or 2 75kpa for propane is obtained 2 Adjust main supply regulator until at least 1 25kpa for natural gas or 3kpa for propane...

Страница 24: ...24 bromic com heat APPENDIX A Note For clearance from combustible materials see page 7...

Страница 25: ...25 bromic com heat APPENDIX A CONTINUED...

Страница 26: ...ERMANY 8 DK DENMARK 9 EE ESTONIA 10 ES SPAIN 11 FI FINLAND 12 FR FRANCE 13 GB GREAT BRITAIN 14 GR GREECE 15 HR CROATIA 16 HU HUNGARY 17 IE IRELAND 18 IS ICELAND 19 IT ITALY 20 LT LITHUANIA 21 LU LUXEM...

Отзывы: