Bromic Heating DC100-S Скачать руководство пользователя страница 6

6 | 

P a g e      

 

R e v 4 . 1

 

 

APPLIANCE DIMENSIONS 

 

 

COMPONENTS AND PARTS 

 

 

 

 

DC100NG-S & DC100-S 

 

DC200NG-S  & DC200-S 

PARTS INDEX  

1. Body 

3. Outer Ring Brass Cap 

5. Tray 

7. Rubber Leg 

2. Trivet 

4. Inner Ring Brass Cap 

6. Burner Head 

8. Knob  

9. Thermocouple 

 

 

 

 
OPERATING INSTRUCTIONS 

USING THE APPLIANCE 

Follow these steps when operating the appliance: 

LIGHTING THE APPLAINCE 

1.  Make sure the ignition knob set to the ‘OFF’ position. 
2.  Push in and turn the ignition knob anti-clockwise until a “click”  

sound is heard. Keep the control knob depressed for 5 seconds  
allow the flame (thermocouple) safeguard to operate. 

      Release the control knob. 
      Turn the control knob to the required setting. 

If the burner does not come on, turn the control knob to the off setting and repeat the steps 
above. This time, press and hold the control knob for longer (up to 10 seconds). 

      

Warning – Risk of deflagration! 

3.  If after 10 seconds the flame does not ignite, switch off the burner and open a nearby window 

or door. Wait at least one minute before trying to switch the burner back again. If the flame still 
does not ignite contact Bromic Pty Ltd or an authorized agent for assistance. 

4.  Flame  abnormalities.  If  any  of  the  following  are  observed  during  operation  of  the  appliance: 

Carbon build up on the appliance or pans, Excessive yellow tipping of the burner flame, flames 
lifting  off  the  burner  ports  or  flashing  back.  Flame  abnormality  may  be  due  to  gas  supply 
restriction or blockage of burner ports or venturi. Gas spillage may occur if the burner inlet is 
partially blocked by spider webs the gas may ignite around the burner inlet. You should cease 
using the appliance and contact Bromic Pty Ltd or an authorized agent for assistance. 

 

Lighting the cooker 

ON 

OFF 

Содержание DC100-S

Страница 1: ...ory regulation s Refer to AS NZS 5601 1 for piping size details GAS PRESSURE REGULATOR DETAILS FOR NG MODELS The NG model they must be installed in accordance with AS NZS 5601 1 by an authorised gas fitter plumber A natural gas regulator Maxitrol RV20LM AGA Approval No 3088 with an outlet pressure of 1 0kPa is included with this appliance FOR LP MODELS Where the LPG models are connected to a perma...

Страница 2: ...e and its effect on surrounding surfaces clothing and skin Children or the elderly should be supervised when near this appliance Do not hang clothing or other flammable material on or near this appliance Always keep flammable materials away from the appliance Make sure that you use cooking woks pots or pans that sit firmly on the trivet Do not use pots that are too small large for the burner size ...

Страница 3: ...aximum performance economy and safety of operation Always ensure that adequate fresh air is provided for ventilation The minimum volume of the room where appliance is installed 1 5 M2 per MJ Refer to AS NZS 5601 1 for details of the necessary ventilation requirements including the size of the openings The appliance must only be operated on a level firm non combustible surface This appliance shall ...

Страница 4: ... LP Gas Models Where the LPG models are connected to a permanently fixed reticulated LP Gas supply they must be installed in accordance with AS NZS 5601 1 by an authorised gas fitter plumber Where the LPG models are used in quasi outdoor indoor areas such as an alfresco or balcony situation the purchaser consumer may use an approved certified LP Gas regulator and hose assembly connected to a 4 5 o...

Страница 5: ...e is off 7 The consumer fully understands the safety precautions operation and maintenance 8 The operation of the ignition system is satisfactory 9 The operation of the flame thermocouple safeguard is satisfactory 10 Flame abnormalities If any of the following are observed during operation of the appliance Carbon build up on the appliance or pans Excessive yellow tipping of the burner flame flames...

Страница 6: ...s time press and hold the control knob for longer up to 10 seconds Warning Risk of deflagration 3 If after 10 seconds the flame does not ignite switch off the burner and open a nearby window or door Wait at least one minute before trying to switch the burner back again If the flame still does not ignite contact Bromic Pty Ltd or an authorized agent for assistance 4 Flame abnormalities If any of th...

Страница 7: ...pan over the burner not to one side Otherwise it could tip over Place the pans on the pan supports never directly on the burner Make sure that the pan supports and burner caps are correctly positioned before using the appliance Pans should be placed on the hob carefully Do not strike the hob and do not place excessive weight on it CAUTION CORRECT PLACEMENT OF UTENSILS DO NOT SPRAY AEROSOLS IN THE ...

Страница 8: ... clean these areas with a product that is suitable for stainless steel SERVICE INSTRUCTIONS FOR AUTHORISED PERSON such as LICENSED GAS FITTER OR PLUMBER DO NOT MODIFY THIS APPLAINCE Access to components under the hob Ensure the appliance is cool before attempting any service and the gas supply is turned off or disconnected Disconnect regulator or hose from gas supply Remove trivet s spillage bowls...

Страница 9: ... 56 mm x 2 openings Primary air shutter in fully open position LP Gas Main burner inner primary aeration control 12 14 mm x 2 openings Primary air shutter in fully open position TROUBLESHOOTING Problem Possible Cause Solution No Ignition Main Gas Valve is not turned on Air trapped in the gas hose Electronic ignition is wet or dirty The safety valve is not open Turn off the gas valve once and then ...

Страница 10: ...50 0 68 Dimensions mm H 145x W 300x D 382 H 145x W 720x D 382 Net Weight kg 3 7 6 6 Gas Type UNIVERSL LP GAS Gas Pressure kPa 2 75 Gas Fitting 5 8 18 UNF thread known as 3 8 SAE male fitting Ignition System Piezo electric Country of Origin China AGA Approval No 7092 G Bromic Pty Ltd and their appointed agents will not be liable in respect of any misuse which is not in accordance with the instructi...

Страница 11: ...e the Purchaser for any investigation or service including parts and labour which is found not to be connected to a warranty issue Bromic is not liable for any incidental or consequential loss or damage arising from any cause whatsoever including but not limited to loss or damage arising from misuse of the Ring Burner neglect accident improper installation unauthorised modification unauthorised at...

Страница 12: ...12 P a g e R e v 4 1 Call 1300 276 642 1300 BROMIC or 61 2 9426 5222 Email us plumbing bromic com au Visit www bromic com plumbing ...