HEATER INSTALLATION

INSTALLATION CLEARANCES 
FOR 2000W & 3000W MODELS

2000W & 3000w models must be installed with the minimum 

installation clearances shown in below diagrams. 2000W & 

3000W models are supplied with short mounting brackets to 

be used for both ceiling & wall mounting.

INSTALLATION CLEARANCES 
FOR 4000W & 6000W MODELS

4000W & 6000W models must be installed with the minimum installation clearances shown in below diagrams. 4000W 

& 6000W models are supplied with long mounting brackets to be used for both ceiling & wall mounting.

Alternatively, short mounting brackets can be used for wall mounting of the 4000W & 6000W models to position the 

heater closer to the wall. Short mounting brackets must be purchased separately.

 250 

300 

300 

 45° 

 120 

 45° 

2400

CEILING MOUNTING MINIMUM 

CLEARANCE TO FLOOR  

300 

 330

 

450

300 

 30° 

2400

CEILING MOUNTING MINIMUM 

CLEARANCE TO FLOOR  

1800/96” (8’)

WALL MOUNTING MINIMUM 

CLEARANCE TO FLOOR  

1800/96” (8’)

WALL MOUNTING MINIMUM 

CLEARANCE TO FLOOR  

30

° 

 150 

 110 

 10” 

12” 

12” 

 5” 

12” 

 13”

18”

12” 

 4” 

 6” 

 250 

300 

300 

 45° 

 120 

 45° 

2400

CEILING MOUNTING MINIMUM 

CLEARANCE TO FLOOR  

300 

 330

 

450

300 

 30° 

2400

CEILING MOUNTING MINIMUM 

CLEARANCE TO FLOOR  

1800/96” (8’)

WALL MOUNTING MINIMUM 

CLEARANCE TO FLOOR  

1800/96” (8’)

WALL MOUNTING MINIMUM 

CLEARANCE TO FLOOR  

30

° 

 150 

 110 

 10” 

12” 

12” 

 5” 

12” 

 13”

18”

12” 

 4” 

 6” 

           WARNING

DO NOT MOUNT THE HEATER VERTICALLY!

Heater MUST be installed so that the tube elements 

are horizontal. Failure to do this will cause the heating 

element within the tube to sag and cause premature 

burnout. Installing vertically will void the manufacturers 
warrant

y. 

!

!

           WARNING

DO NOT MOUNT THE HEATER VERTICALLY!

For outdoor installation heater must be mounted with 

face of heater angled down.

For longest product life & to maintain product 

appearance mount heater under cover & protect from 

rain & weather whenever possible.

!

           WARNING

ES MODELS MUST NOT BE MOUNTED WITH CEILING 

RECESS MOUNTING KITS.

Содержание COBALT SMART-HEAT 2000W

Страница 1: ...OUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE COBALT SMART HEAT ELECTRIC HEATER BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS COBALT...

Страница 2: ...of of leaving the room on their own unless constant supervision is provided Patent Pending Australian Registered Design 338721 BROMIC HEATING Head Office 10 Phiney Place Ingleburn NSW 2565 Australia T...

Страница 3: ...URES 5 SPECIFICATIONS 5 HEATER INSTALLATION 6 REMOVE PACKAGING MATERIAL 6 INSTALLATION CLEARANCES 7 CEILING WALL MOUNTING 8 CHAIN SUSPENSION 8 TUBE SUSPENSION 9 ELECTRICAL INSTALLATION 10 WIRING DIAGR...

Страница 4: ...eater in an explosive environment such as areas where petrol or other flammable liquids or vapours are stored Clothing or other flammable materials should not be hung from the heater or placed on or n...

Страница 5: ...waste disposal service or the place of purchase PRODUCT OVERVIEW IMPORTANT NOTES AND WARNINGS CONTINUES PRODUCT FEATURES The Cobalt Smart Heat Electric heaters are designed to provide efficient spot h...

Страница 6: ...e cover by pulling it out from under the edge of the heater and in between the reflector 3 Remove packing material around heating elements 4 Check element markings at both ends of heater Ensure marks...

Страница 7: ...NTING MINIMUM CLEARANCE TO FLOOR 1800 96 8 WALL MOUNTING MINIMUM CLEARANCE TO FLOOR 1800 96 8 WALL MOUNTING MINIMUM CLEARANCE TO FLOOR 3 0 150 110 10 12 12 5 12 13 18 12 4 6 250 300 300 45 120 4 5 240...

Страница 8: ...x suply power cord to ceiling chain with cable ties Mounting Hole Centres Heater Position 2620213 3000W 2620215 6000W 2620212 2000W 2620214 4000W 1 CEILING WALL MOUNTING 1 Mark mounting hole centres...

Страница 9: ...ts 9 Make electrical connection from suspension tube power cord to power from ceiling as per electrical installation instructions in this manual TUBE SUSPENSION SOLD SEPARATELY TUBE SUSPENSION SOLD SE...

Страница 10: ...y before installing or servicing this heater Read and follow installation clearance requirements outlined in this manual The Appliance MUST be connected to a properly grounded electrical source Discon...

Страница 11: ...permanently installed and hard wired by an authorised licenced person Junction Box AC Heater Element 1 240 V AC SINGLE PHASE EARTH WIRE Heater Element 2 WIRING DIAGRAM COBALT SMART HEAT ELECTRIC OPTIO...

Страница 12: ...may occur Disconnect from electrical supply before servicing this heater WARNING Servicing and maintenance MUST be carried out by an authorised and licensed person only 1 Remove the wire cover by pull...

Страница 13: ...ersists TROUBLESHOOTING Version 1 1GB Revised 30 07 2015 No Description PART NUMBER 1 Heater Cobalt electric 2000W 240V EU BH0610005 2 Heater Cobalt electric 3000W 240V EU BH0610006 3 Heater Cobalt el...

Отзывы: