![Bromic Heating COBALT SMART-HEAT 2000W Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/bromic-heating/cobalt-smart-heat-2000w/cobalt-smart-heat-2000w_installation-instruction-and-service-manual_2818227007.webp)
7
www.bromicheating.com
HEATER INSTALLATION
INSTALLATION CLEARANCES
FOR 2000W & 3000W MODELS
2000W & 3000w models must be installed with the minimum
installation clearances shown in below diagrams. 2000W &
3000W models are supplied with short mounting brackets to
be used for both ceiling & wall mounting.
INSTALLATION CLEARANCES
FOR 4000W & 6000W MODELS
4000W & 6000W models must be installed with the minimum installation clearances shown in below diagrams. 4000W
& 6000W models are supplied with long mounting brackets to be used for both ceiling & wall mounting.
Alternatively, short mounting brackets can be used for wall mounting of the 4000W & 6000W models to position the
heater closer to the wall. Short mounting brackets must be purchased separately.
250
300
300
45°
120
45°
2400
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
300
330
450
300
30°
2400
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
1800/96” (8’)
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
1800/96” (8’)
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
30
°
150
110
10”
12”
12”
5”
12”
13”
18”
12”
4”
6”
250
300
300
45°
120
45°
2400
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
300
330
450
300
30°
2400
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
1800/96” (8’)
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
1800/96” (8’)
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
30
°
150
110
10”
12”
12”
5”
12”
13”
18”
12”
4”
6”
WARNING
DO NOT MOUNT THE HEATER VERTICALLY!
Heater MUST be installed so that the tube elements
are horizontal. Failure to do this will cause the heating
element within the tube to sag and cause premature
burnout. Installing vertically will void the manufacturers
warrant
y.
!
!
WARNING
DO NOT MOUNT THE HEATER VERTICALLY!
For outdoor installation heater must be mounted with
face of heater angled down.
For longest product life & to maintain product
appearance mount heater under cover & protect from
rain & weather whenever possible.
!
WARNING
ES MODELS MUST NOT BE MOUNTED WITH CEILING
RECESS MOUNTING KITS.