Digital thermostat failures
Alarm signals for Dixel thermostat;
Alarm signals for Carel thermostat;
Setting the digital thermostat values other than the factory settings are completely under the
user's responsibility. Our company shall not be held responsible for the material and moral losses
that may arise in connection thereto.
MESSAGE REASON
PROCEEDINGS TO BE FOLLOWED
P1
Room sensor failure
Check the sensor connection
P2 sen
Evaporator sensor failure
Check the sensor connection before replacing the sensor.
HA pa-
Maximum temperature alarm
Check compressor operation and relevant parameter values.
LA pa-
Maximum temperature alarm
Check compressor operation and relevant parameter values.
EA
External alarm
Alarm stops automatically when digital entry is deactivated.
MESSAGE REASON
PROCEEDINGS TO BE FOLLOWED
EO
Control sensor 1 failure
(Control)
Check the sensor
E1
Control sensor 2 failure
(Defrost)
Check the sensor and d0=0/1/4,F0=1
E2
Control sensor 3 failure
(Condenser)
Check the sensor and whether it is (A4=10)
IA
External alarm
Check external alarm outlets or A4 and A7 parameters.
dOr
Open door alarm
Check that the door is closed or A4 and A7 parameters.
LO
Low temperature alarm
Alarm will be turned-off automatically when the temperature
returns to the set value range. Also check the set value.
HI
High temperature alarm
Alarm will be turned-off automatically when the temperature
returns to the set value range. Also check the set value. Check
whether the cooling system runs properly.
EE/Eer
Unit parameter failure
Check the parameters.
EF
Operating parameter failure
Check dT,dP and d4 parameters; defrost effect. Alarm will be closed
automatically when defrost operation finishes.
ED
Defrost completed out of
its time
25
dT, dP and d4 parameters; Check defrost effect. When
defrosting is finished normally, the alarm will turn off.