Brocade Communications Systems SilkWorm 3800 Скачать руководство пользователя страница 58

Glossary-12

SilkWorm 3800 Hardware Reference

Содержание SilkWorm 3800

Страница 1: ...Publication Number 53 0001576 06 SilkWorm 3800 Hardware Reference Manual...

Страница 2: ...shall have no liability or responsibility to any person or entity with respect to any loss cost liability or damages arising from the information contained in this book or the computer programs that...

Страница 3: ...he SilkWorm 3800 1 3 Chapter 2 Installing and Configuring the SilkWorm 3800 Installation and Safety Considerations 2 1 Items Included With the SilkWorm 3800 2 2 Setting Up the SilkWorm 3800 as a Stand...

Страница 4: ...ions A 3 Environmental Requirements A 3 General Specifications A 4 Data Transmission Ranges A 5 Memory Specifications A 5 Fibre Channel Port Specifications A 5 Serial Port Specifications A 5 POST and...

Страница 5: ...Preface Updated Technical Support information Added formatting conventions Installation chapter Added rack kit procedure Modified configuration procedure Airflow changed to 25 cubic feet per minute p...

Страница 6: ...rpose bold text identifies command names identifies GUI elements identifies keywords operands identifies text that you must enter at the GUI or CLI italic text provides emphasis identifies variables i...

Страница 7: ...ion for Fabric OS optional software Brocade Advanced Zoning User s Guide Brocade ISL Trunking User s Guide Brocade Advanced Web Tools User s Guide Brocade Advanced Performance Monitoring User s Guide...

Страница 8: ...pologyshow command Detailed description of the problem and specific questions Description of any troubleshooting steps already performed and results Switch Serial Number The switch serial number and c...

Страница 9: ...he highest common speed of all devices connected to port Port interfaces compatible with small form factor pluggable SFP transceivers both short wavelength SWL and long wavelength LWL Universal and se...

Страница 10: ...allows creation of trunking groups of ISLs between adjacent switches For more information about trunking refer to the Brocade ISL Trunking User s Guide Non Port Side of the SilkWorm 3800 Figure 1 2 sh...

Страница 11: ...l Out of band Support In band Support Command line interface Up to two admin sessions and four user sessions at same time For more information refer to the Brocade Fabric OS Procedures Guide and the B...

Страница 12: ...on refer to the Brocade ISL Trunking User s Guide Brocade Fabric Watch For information refer to the Brocade Fabric Watch User s Guide Brocade Advanced Performance Monitoring For information refer to t...

Страница 13: ...and operation of the switch Ensure the following electrical requirements are met Primary AC Input 100 240 VAC switch auto senses input voltage 47 63 HZ Correctly wired primary outlet with circuit prot...

Страница 14: ...the standard shipment of the SilkWorm 3800 The SilkWorm 3800 switch containing two fan assemblies and one or two power supplies Slide Rack Mount Kit with installation instructions One accessory kit c...

Страница 15: ...the edge of the cabinet To allow the non port side of the switch to slide out the cool air side of the cabinet In this installation the port side of the switch is set three inches back from the edge...

Страница 16: ...to attach inner rails to switch 4 to attach Items 11 12 to switch 10 8 Nut Bar Rack 3 hole 4 Hardware specific to installing a switch in a cabinet that has square holed rails 9 Washer Alignment 12 10...

Страница 17: ...ch pounds d Repeat with the second inner slide rail on the other side of the switch 3 Optional Install the Rack Mount Brackets on the switch These brackets prevent the switch from sliding out of the c...

Страница 18: ...l the power cords into the clips with the receptacle end towards the closed end of the slide rail To allow the switch to slide out the cool air side of the cabinet Install the power cords into the cli...

Страница 19: ...ps 7a through 7d with the second slide rail 8 Install the switch in the cabinet a Position the switch next to the cabinet as shown in Figure 2 1 or Figure 2 2 as appropriate and align then insert the...

Страница 20: ...haust air Side of the Cabinet Caution procedure for use on the chassis use the exact screws specified in the To prevent damage to the switch Item 2 4x Item 1 2x Item 3 8x Item 4 8x Item 5 6x Item 8 4x...

Страница 21: ...Side of the Cabinet Item 16 2x Caution procedure for use on the chassis use the exact screws specified in the To prevent damage to the switch Item 2 4x Item 1 2x Item 3 4x Item 4 4x Item 5 6x Item 8...

Страница 22: ...lkWorm 3800 must be configured to ensure correct operation within a network and fabric For instructions about configuring the switch to operate in a fabric containing switches from other vendors refer...

Страница 23: ...he exposed RJ 45 connector into the RJ 45 serial port on the workstation c Disable any serial communication programs running on the workstation d Open a terminal emulator application such as HyperTerm...

Страница 24: ...IP address on the label provided for this purpose on the port side of the SilkWorm 3800 e Record the IP address on the label provided for this purpose on the SilkWorm 3800 f If the serial port is no l...

Страница 25: ...itch by entering the switchenable command 8 Optional Specify any custom status policies a Enter the switchstatuspolicyset command at the prompt This command sets the policy parameters that determine t...

Страница 26: ...tional For information about LED patterns refer to Interpreting LED Activity on page 3 1 12 Verify the correct operation of the SilkWorm 3800 by entering the switchshow command from the workstation Th...

Страница 27: ...at least one meter of slack for each port cable This provides room to remove and replace the switch allows for inadvertent movement of the rack and helps prevent the cables from being bent to less tha...

Страница 28: ...2 16 SilkWorm 3800 Hardware Reference Installing and Configuring the SilkWorm 3800 2...

Страница 29: ...off To power the switch off power off both power supplies if both are installed by flipping each AC power switch to O Note Removing all power from the switch triggers a system reset All devices are re...

Страница 30: ...Port Speed LED 16x Table 3 1 Port Side LED Patterns During Normal Operation LED Name Location Color of LED Status of Hardware Recommended Action Switch Status Power LED Below serial port No light Swi...

Страница 31: ...No action required Slow flashing orange on 1 second off 1 second Port is disabled result of diagnostics or portDisable command If all ports are slow flashing orange the switch may be disabled Enable p...

Страница 32: ...tion LED Name Location Color of LED Status of Hardware Recommended Action Port Readiness LED Center of non port side No light Switch is off or boot is not complete or boot failed Verify switch is on a...

Страница 33: ...ble 3 2 on page 3 4 Verify the switch prompt displays on the terminal of a computer workstation connected to the switch If the switch prompt does not display when POST completes press ENTER If the swi...

Страница 34: ...ic diagnostic tests refer to the Brocade Fabric OS Procedures Guide Field Replaceable Units FRUs You can replace the power supplies fan assemblies and motherboard in the field without the use of speci...

Страница 35: ...ine whether a fan assembly requires replacing Check the Fan Failure LED on the face of the fan assembly see LEDs On the Non Port Side of the Switch on page 3 4 Enter the fanshow command In Web Tools c...

Страница 36: ...3 8 SilkWorm 3800 Hardware Reference Operating the SilkWorm 3800 3...

Страница 37: ...ced air cooling that flows from the non port side of the switch to the port side 16 fibre channel ports compatible with SFP transceivers SWL and LWL One RS 232 serial port DB 9 connector One IEEE comp...

Страница 38: ...n the standards listed in Table A 4 on page A 4 under Immunity Thermal A minimum air flow of 50 cubic feet minute 35 7 cubic meters hour available in the immediate vicinity of the switch Ambient air t...

Страница 39: ...er consumption 90 102 Watts depending on transceiver vendor Input voltage 100 240 VAC nominal 80 efficiency auto ranging Input line frequency 47 63 Hz Harmonic distortion Active power factor correctio...

Страница 40: ...vel 3 for Electrostatic Discharge IEC 61000 4 3 Severity Level 3 for Radiated Fields IEC 61000 4 4 Severity Level 3 for Fast Transients IEC 61000 4 5 Severity Level 3 for Surge Voltage IEC 61000 4 6 C...

Страница 41: ...ance on page A 7 The ports are capable of operating at 2 125 Gbit sec or 1 0625 Gbit sec and are able to auto sense the highest speed of which all attached devices are capable Serial Port Specificatio...

Страница 42: ...booted or the system is reset Total boot time with POST is a minimum of three minutes POST can be skipped after subsequent reboots by using the fastboot command For more information about this command...

Страница 43: ...n is enabled Regulatory Compliance FCC Warning USA only This equipment has been tested and complies with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules These limits are...

Страница 44: ...ws and standards Electromagnetic Compatibility EMC Directive 89 336 EEC and the Complementary Directives 92 31 EEC and 93 68 EEC Low Voltage Directive LVD 73 23 EEC and the Complementary Directive 93...

Страница 45: ...y with these standards may emit light that is hazardous to the eyes Warning Do not attempt to replace the RTC battery There is danger of explosion if the battery is incorrectly replaced or disposed of...

Страница 46: ...United Kingdom EN 60950 92 A1 93 A2 93 A3 95 A4 96 A11 97 73 23 EEC TUV Germany only 89 336 EEC EN 55022 1998 Class A EN 55024 Immunity EN60825 1 1994 A11 2 EN 61000 4 2 Severity Level 3 for Electrost...

Страница 47: ...mming interface A defined protocol that allows applications to interface with a set of services arbitrated loop A shared 100 MBps fibre channel transport structured as a loop Can support up to 126 dev...

Страница 48: ...es can be cascaded up to 239 switches with a recommended maximum of seven interswitch links no path longer than eight switches See also fabric ISL chassis The metal frame in which the switch and switc...

Страница 49: ...data words See also frame ordered set transmission word defined zone configuration The set of all zone objects defined in the fabric May include multiple zone configurations See also enabled zone conf...

Страница 50: ...ociation An international organization of fibre channel industry professionals Among other things provides oversight of ANSI and industry developed standards FCP Fibre channel protocol Mapping of prot...

Страница 51: ...port to simultaneously transmit and receive frames See also half duplex Fx_Port A fabric port that can operate as either an F_Port or FL_Port See also F_Port FL_Port gateway Hardware that connects in...

Страница 52: ...to overlapping domain IDs or nonidentical parameters such as E_D_TOVs See also E_Port IU Information unit A set of information as defined by either upper level process protocol definition or upper le...

Страница 53: ...through a trunking group One of the ports that is in the first ISL in the trunking group is designated as the master port for that group See also ISL trunking MIB Management information base An SNMP s...

Страница 54: ...ks between each pair of communicating entities See also topology port cage The metal casing extending out of the fibre channel port on the switch and into which a GBIC or SFP transceiver can be insert...

Страница 55: ...nges to be sent from the switch to specified nodes SAN Storage area network A network of systems and storage devices that communicate using fibre channel protocols See also fabric SDRAM The main memor...

Страница 56: ...rithm transmission word A group of four transmission characters trap SNMP The message sent by an SNMP agent to inform the SNMP management station of a critical error See also SNMP trunking See ISL tru...

Страница 57: ...osts attached to the same fabric and configured as being in the same zone Devices and hosts within the same zone have access permission to others in the zone but are not visible to any outside the zon...

Страница 58: ...Glossary 12 SilkWorm 3800 Hardware Reference...

Страница 59: ...itch A 1 configuring IP address 2 12 SilkWorm 3800 for operation 2 10 status policies 2 13 terminal emulator application 2 11 D diagnostic tests about 3 6 LED indicators 3 1 documentation related 1 vi...

Страница 60: ...A 4 ethernet port A 1 fibre channel port A 5 serial port A 1 A 5 speed 1 1 port side description of 1 2 LEDs 3 2 POST duration A 6 error messages 3 5 A 6 interpreting 3 5 LED indicators 3 1 specifica...

Страница 61: ...ial port A 5 status policies configuring 2 13 switch components A 1 field replaceable parts 3 6 physical dimensions A 2 specifications A 1 weight A 2 T temperature requirements A 3 terminal emulator a...

Страница 62: ...Index 4 SilkWorm 3800 Reference Manual...

Отзывы: