2. Access the CONFIG level of the CLI by entering the following command.
FWSSwitch# configure terminal
FWSSwitch(config)#
3. Enter the following command to set the super-user password.
FWSSwitch(config)# enable super-user-password <text>
NOTE
You must set the super-user password before you can set other types of passwords.
4. Enter the following commands to set the port configuration and read-only passwords.
FWSSwitch(config)# enable port-config-password <text>
FWSSwitch(config)# enable read-only-password <text>
NOTE
If you forget your super-user password, refer to
“Recovering from a lost password”
on page 30.
Syntax: enable super-user-password | read-only-password | port-config-password <
text
>
Passwords can be up to 32 characters long.
Recovering from a lost password
By default, the CLI does not require passwords. However, if someone has configured a password for
the device but the password has been lost, you can regain super-user access to the device using
the following procedure.
NOTE
Recovery from a lost password requires direct access to the serial port and a system reset.
Recover from a lost password.
1. Start a CLI session over the serial interface to the Brocade device.
2. Reboot the device.
3. While the system is booting, before the initial system prompt appears, enter b to enter the boot
monitor mode.
4. Enter no password at the prompt. (You cannot abbreviate this command.)
5. Enter boot system flash primary at the prompt. This command causes the device to bypass the
system password check.
After the console prompt reappears, assign a new password.
Configuring IP addresses
You must configure at least one IP address using the serial connection to the CLI before you can
manage the system using the other management interfaces.
Brocade devices support both classical IP network masks (Class A, B, and C subnet masks, and so
on) and Classless Interdomain Routing (CIDR) network prefix masks:
Содержание FWS624
Страница 6: ...vi Brocade FastIron WS Hardware Installation Guide 53 1002188 01 DRAFT BROCADE CONFIDENTIAL...
Страница 10: ...x Brocade FastIron WS Hardware Installation Guide 53 1002188 01 DRAFT BROCADE CONFIDENTIAL...
Страница 18: ...8 Brocade FastIron WS Hardware Installation Guide 53 1002188 01 Hardware features 1 DRAFT BROCADE CONFIDENTIAL...
Страница 74: ...64 Brocade FastIron WS Hardware Installation Guide 53 1002188 01 Danger B DRAFT BROCADE CONFIDENTIAL...