108
Brocade FastIron X Series Chassis Hardware Installation Guide
53-1001723-02
Managing management module redundancy
5
shows how the files are synchronized between the active module and the standby
module.
FIGURE 39
Active and standby management module file synchronization
Manually switching over to the standby management module
This section describes how to manually switch the role of active management module from the
currently active module to the standby module.
NOTE
Hitless switchover
is also supported. An enhancement to the manual switchover feature, a hitless
switchover enables a switchover of the active management module to standby module without
interrupting switched traffic. For details, refer to
You can cause the system to switch over to the standby module (and thus make it the active
module). To do so, enter the following command.
FastIron# switch-over-active-role
Active Management Module
Synchronized at startup
or switchover
Also can be immediately
synchronized using the CLI
Startup-config also
automatically updated
with
write memory
command
Standby Management Module
Startup-config file
Flash code
Boot code
Boot code
Flash code
Startup-config file
Содержание FastIron SX 1600
Страница 8: ...viii Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 ...
Страница 96: ...68 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Verifying proper operation 2 ...
Страница 114: ...102 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Removing MAC address entries 4 ...
Страница 200: ...188 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Detailed procedure A ...
Страница 204: ...192 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Russia B ...