![Brobo FA 3000K Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/brobo/fa-3000k/fa-3000k_product-and-maintenance-manual_2817132006.webp)
2. INSTALLATION OF THE MACHINE
2.1
Unpacking and Handling the Machine
FA 3000K consists of the following major components (Figure 2.1):
Brobo S350D cold saw with automatic actuation
F3000 automatic material feeder
Electrical control box with 10 inch HMI touch screen
Figure 2.1
– FA 3000K Major Components
FA 3000K will arrive at your workshop in three packages:
FA Cold saw unit with electrical box.
Material feeder unit.
Spare table with the control tablet.
Cold saw unit is the heaviest of the components, hence needs to be placed in position first with the rest of the
machine to be built around it. When selecting suitable space keep in mind the space requirements of the feeder
unit which is 3+ m long.
When happy with unit position, unpack the material feeder and proceed first to attach the feeder legs to the main
body (using four M8 bolts), and then to attach the material feeder itself to the cold saw unit (two M10 bolts). Refer
to Section 5 for machine assembly drawings.
Place the electrical box as illustrated in Figure 2.1, leaving the Operator in optimum position, accessible to
controls and the main cutting area, but out of the way of the machine cutting and feeding zone.
When determining location for the machine, ensure that floor is as level as possible and that the requirements
from Section 2 (below) and safety precautions in Section 6 are adequately met. Additionally for best performance
ensure that the feeder working table is leveled, adjusting the two standing feet if necessary.
When sourcing the power supply cable, check that they are within the acceptable standards (Section 6). Install the
power cable as per electrical schematics in Figures 5.5 and 5.6 (Section 5). The installation of the Earthing
system must comply with the
IEC Standards Part 195: Earthing and Protection Against Electric Shocks 1998
.
Insufficient lighting during the unit operation would constitute a safety hazard according to the
ISO 8995 – 2002
‘Lighting of Indoor Workplaces’
. For this reason, the user must provide adequate lighting in the working area
(500 LUX), while also preventing dazzling illumination sources.
Material
Feeder
Unit
Electrical
Box
FA
Cold Saw
Unit
Main Saw
Guard
10 inch
Touch Screen
Tablet
Feeder
Guard
Steel Roller
Table
20 August 2016
Installation of the Machine
3
Содержание FA 3000K
Страница 2: ......
Страница 20: ...20 August 2016 Layouts Assemblies and Spare Parts 17 ...
Страница 21: ...20 August 2016 Layouts Assemblies and Spare Parts 18 ...
Страница 22: ...20 August 2016 Layouts Assemblies and Spare Parts 19 ...
Страница 23: ...20 August 2016 Layouts Assemblies and Spare Parts 20 ...
Страница 24: ...20 August 2016 Layouts Assemblies and Spare Parts 21 ...
Страница 25: ...20 August 2016 Layouts Assemblies and Spare Parts 22 ...
Страница 26: ...20 August 2016 Layouts Assemblies and Spare Parts 23 ...
Страница 27: ...20 August 2016 Layouts Assemblies and Spare Parts 24 ...
Страница 28: ...20 August 2016 Layouts Assemblies and Spare Parts 25 ...
Страница 29: ...20 August 2016 Layouts Assemblies and Spare Parts 26 ...
Страница 30: ...20 August 2016 Layouts Assemblies and Spare Parts 27 ...
Страница 31: ...20 August 2016 Layouts Assemblies and Spare Parts 28 ...
Страница 32: ...20 August 2016 Layouts Assemblies and Spare Parts 29 ...
Страница 33: ...20 August 2016 Layouts Assemblies and Spare Parts 30 ...
Страница 34: ...20 August 2016 Layouts Assemblies and Spare Parts 31 ...