INDICATOR LIGHTS
The series of indicator lights on the Display Panel check for specific conditions that make the
VF-2 fryer safe to operate. The unit will not start or continue a cook cycle if any of the following
indicator lights are lit.
Power to the controller and heating element are electronically disconnected when:
-
Access Door is Open
-
Air filter is not in place
-
Element is in the
UP
position
-
Grease filter is not in place
-
Air Flow is below acceptable level
-
High Limit Control has been tripped
(A)
The Product Door may be opened without interrupting the cooking cycle. However, cycle cannot
be started until product door is closed.
(B)
Air Filter should be replaced at least every 3 months or sooner if volume is high.
COMPLAINT
CAUSE
REMEDY
Product Door
(A)
1. Product Door Open
2. Failed switch
1. Close product door
2. Push power OFF button
Contact service person
Access Door
1. Access Door Open
2. Failed switch
1. Close Access door
2. Push power OFF button
Contact service person
Element Up
1. Element in raised position
2. Failed switch
1. Lower element
2. Push power OFF button
Contact service person.
Air Flow
1. Fan failure
2. Failed switch
1. Push power OFF button
Contact service person
2. Push power OFF button
Contact service person
Air Filter
(B)
1. Air Filter not in place
2. Failed switch
1. Insert Air Filter all the way
2. Push power OFF button
Contact service person
Grease Filter
1. Grease Filter not in place
2. Failed switch
1. Insert Grease Filter
2. Push power OFF button
Contact service person
High Limit Reset
1. Oil exceeded maximum
temperature
2. Probe Failure
Push power OFF
Contact service person
Fire System
1. 6 months operation has
elapsed.
1. Contact certified Fire
Service Personnel for
required maintenance
inspection.
broaster.com Manual #16421 5/06 Rev 4/14
Содержание VF-2
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 14: ...3 4 WIRING DIAGRAM VF 2 NO NC C PRESSURE SENSOR P MPL broaster com Manual 16421 10 20 Rev 10 20 ...
Страница 17: ...3 7 NO NC C WIRING DIAGRAM VF 2 effective S N VF2L90xxxx broaster com Manual 16421 10 20 Rev 10 20 ...
Страница 18: ...3 8 broaster com Manual 16421 10 20 Rev 10 20 WIRING DIAGRAM VF 3 VF 2 effective S N VF3J02112 and VF2_02003G ...
Страница 19: ...3 9 WIRING DIAGRAM VF 3i NO NC C PRESSURE SENSOR P MPL broaster com Manual 16421 10 20 Rev 10 20 ...
Страница 21: ...3 11 WIRING DIAGRAM VF 3i effective S N VF3H90xxxx NO NC C broaster com Manual 16421 10 20 Rev 10 20 ...
Страница 22: ...3 12 WIRING DIAGRAM VF 2 EXPORT NO NC C PRESSURE SENSOR P MPL broaster com Manual 16421 10 20 Rev 10 20 ...
Страница 24: ...3 14 WIRING DIAGRAM VF 2 EXPORT effective S N VF2L90xxxx NO NC C broaster com Manual 16421 10 20 Rev 10 20 ...
Страница 25: ...3 15 WIRING DIAGRAM VF 3i EXPORT NO NC C PRESSURE SENSOR P MPL broaster com Manual 16421 10 20 Rev 10 20 ...
Страница 27: ...3 17 WIRING DIAGRAM VF 3i EXPORT effective S N VF3H90xxxx NO NC C broaster com Manual 16421 10 20 Rev 10 20 ...
Страница 30: ......
Страница 34: ......
Страница 36: ......
Страница 54: ......
Страница 58: ......
Страница 62: ......
Страница 64: ......
Страница 68: ......
Страница 69: ......
Страница 70: ...Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...