SMART TOUCH CONTROLLER TIPS
1800E
1800GH
COMPLAINT
CAUSE
REMEDY
REMEDY
Display reads
HEATER FAULT
Oil temperature not rising
properly
* Call for service
*
Remove
anything
causing
a
draft
by
the
unit
(like
a
fan).
*
Turn
on
the
gas
valve.
*
Call
for
service
Display is blank
Screen not calibrated
* With unit off, place finger on screen and hold while
turning unit on. Touch the small box in the upper left
corner until it moves to the upper right corner, then touch
it again until it moves to the lower left corner, then touch
it again until it disappears. Controller will reboot.
* Call for service
Display doesn't
respond when
touched
Display reads
PROBE FAULT
* Probe circuit is open or
shorted
*Probe wires are
connected in reverse
*Temperature changes
more than 100F in two
seconds
* Call for service
* Call for service
Display reads HI
TEMP FAULT
Temp reaches 415F
* Call for service
* Call for service
Display reads
INTERNAL FAULT
Internal fault detected
* Call for service
* Call for service
Display reads
C1 FAULT
C1 contactor is stuck in
the closed position
* Call for service
* Call for service
broaster.com Manual #15459 5/02 Rev: 3/16A
Содержание 2400 Series
Страница 2: ......
Страница 8: ......
Страница 12: ......
Страница 14: ......
Страница 22: ......
Страница 40: ......
Страница 44: ......
Страница 50: ......
Страница 52: ......
Страница 62: ......
Страница 63: ......
Страница 64: ...Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...