XB110L1 Installation Guide

Page 2

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and 

Air Conditioning Engineers (ASHRAE), and the local code 

authorities.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Use only ON/OFF switch, mechanical timer or relay-switched 

control.

8.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit.

9.  This unit must be grounded.

Typical Installation

CAUTION

1

.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  This product is designed for installation in ceilings up to a 

12/12 pitch (45 degree angle). Duct connector must point up. 

DO NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced  

impellers, keep drywall spray, construction dust, etc. off power 

unit.

4.  Please read specification label on product for further 

information and requirements.

45°

45°

•  Installation is the same for:

•  Fits in 2" x 8" ceiling construction.
•  Infinitely adjust the fan position 

between joists from 14" to 24"  
on center.

•  Do not install this fan in a ceiling 

thermally insulated to a value 
greater than R40.

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

ROUND

DUCT*

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

NOT FOR USE IN A COOKING AREA

 Do not install above or inside this area

Floor

Cooking
Equipment

Joists    I-Joists          Trusses

The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and en-

ergy use of the fan. Use the shortest, straighest duct routing possible for best performance, and avoid 

installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce en-

ergy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.

6-inch round rigid metal duct is recommended for best performance.

Содержание XB110L1

Страница 1: ...guide with homeowner Register your product online at www broan com register Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Construction Installation 3 Retrofit Installation 7 Operation 12 Cleaning and Maintenance 12 Troubleshooting 12 Service Parts 13 Warranty 13 2017 Broan ...

Страница 2: ... when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 9 This unit must be grounded Typical Installation CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point up DO NOT MOUNT THIS PRODUCT IN A WALL ...

Страница 3: ...wdriver with a Phillips bit Phillips screwdriver Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 6 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Electrical wiring and supplies per local code requirements 1 Remove Packa...

Страница 4: ...ctor and Ducting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing Insert tab into slot inside Housing Screw from Parts Bag 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting snap ...

Отзывы: