WARNING

 

Before servicing or cleaning unit,

switch power off at service panel and lock the service 

disconnecting means to prevent power from being 

switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel. 

Operation

It is normal for this ventilation fan to take approximately 5 

seconds to start running after it is turned on.

Modes

(For reference, wiring diagrams are on pages 5 and 10.) 

Humidity sensing: 

1. Turn sensor/control wall switch on (make sure manual-

on wall switch is off if it is installed).

2. Sensor monitors humidity level for (a) moderate to rapid

rise or (b) above set-point. 

3. Fan operates at certified airflow rate to reduce humidity.

4. When humidity decreases, fan enters time delay mode.

(See below.)

Manual-on

 (optional manual-on wall switch must be 

installed):

1. Turn manual-on wall switch on (sensor/control wall

switch can be on or off).

2. Fan operates at certified airflow rate.

3. Fan turns off when manual-on wall switch is turned off.

Toggle

 (for manual operation when optional manual-on 

wall switch is not installed or manually activated timed-

off is desired):

1. Turn sensor/control wall switch on (make sure manual-

on wall switch is off if it is installed).

2. Wait at least one-second.

3. Turn switch off for less than one-second.

4. Turn switch back on.

5. Fan will operate at certified airflow rate and enter time

delay mode. (See next.)

Time Delay:  

Fan continues to run until user-adjustable TIME delay has 

passed, then fan turns off.

To Set User-Adjustable Humidity Sensitivity**

Using a small, flat-blade screwdriver, carefully rotate HU-

MIDITY adjustment until arrow points to desired humidity 

level shown in percent relative humidity (%RH).

To Set User-Adjustable Time Delay** 

Using a small, flat-blade screwdriver, carefully rotate TIME 

adjustment until the arrow points to the desired minutes of 

time delay.

**  User-adjustable controls are located in corner of Fan 

Housing behind Grille. 

Содержание XB110HL1

Страница 1: ... INSTRUCTIONS Installer leave this guide with homeowner Easy installation in both new construction and retrofit 2 2 3 7 12 13 13 13 Table of Contents Warnings and Cautions Typical Installation New Construction Installation Retrofit Installation Operation Cleaning and Maintenance Troubleshooting Service Parts 2017 Broan ...

Страница 2: ... use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 9 This unit must be grounded Typical Installation CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in flat ceilings Sensor will not function reliably if product is not installed in flat c...

Страница 3: ...er Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 6 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Electrical wiring and supplies per local code requirements 1 Remove Packaging 2 Install Mounting Frame Page 3 New Const...

Страница 4: ...e Housing 4 Attach Duct Connector and Ducting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing Insert tab into slot inside Housing Screw from Parts Bag Tape 6 Ducting snap ...

Страница 5: ...utomatic operation and off for fan cleaning and maintenance purposes MANUAL ON switch directly turns fan on off MANUAL ON switch is not required to manually turn fan on see page 10 SENSOR CONTROL switch may be located where it is not easily accessed for everyday usage it may need to be labeled and located where it can t be turned on without being seen from fan to comply with local and national cod...

Страница 6: ...sk protects unit during construction Remove before installing Grille Install ceiling material Cut out around Housing Plug in Sensor Plug in Light CAUTION If the blower was unplugged power must be disconnected see page 2 WARNING item 2 before inserting motor plugs into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE ...

Страница 7: ...sting wiring to make sure it is not damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Punch out Mask from packaging See Step 12 1 Remove Packaging 2 Switch Off Power 4 Examine Wiring 3 Enlarge Ceiling Opening and Remove Existing Fan Ruler Pencil Drywall saw Claw hammer or pry bar Utility knife Materials need...

Страница 8: ...5 1 1 2 3 3 Retrofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs Remove screws from Mounting Frame and set aside ...

Страница 9: ... Parts Bag Screws set aside in Step 7 Pull existing wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Ducting and Duct Connector 8 Secure Mounting Frame 9 Snap in Housing snap Tape 6 Ducting ...

Страница 10: ...ity control to be turned on for automatic operation and off for fan cleaning and maintenance purposes Toggle mode can be used to manually turn fan on SENSOR CONTROL switch may be located where it is not easily accessed for everyday usage it may need to be labeled and located where it can t be turned on without being seen from fan to comply with local and national codes LINE IN GRD WHT BLK GRD WHT ...

Страница 11: ...ded place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille Screws from Parts Bag CAUTION Power must be disconnected see page 2 WARNING item 2 before inserting motor plugs into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE 2 3 4 1 Connect the sensor Connect the light ...

Страница 12: ...rn manual on wall switch on sensor control wall switch can be on or off 2 Fan operates at certified airflow rate 3 Fan turns off when manual on wall switch is turned off Toggle for manual operation when optional manual on wall switch is not installed or manually activated timed off is desired 1 Turn sensor control wall switch on make sure manual on wall switch is off if it is installed 2 Wait at l...

Страница 13: ...N section at the top of this page Symptom Fan does not run Check for an open fuse or circuit breaker in the build ing s service panel Check that the two 2 plug in connections for the Motor and the Control are seated firmly in place Check two 2 plug in connections for Sensor and its Control are seated firmly in place Check that the Blower Wheel spins freely Symptom Humidity mode does not operate fa...