![Broan ULTRA SILENT QTXE050 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/broan/ultra-silent-qtxe050/ultra-silent-qtxe050_instructions-manual_2816395002.webp)
Page
MODELS QTXE050 • QTXE080 • QTXE110 • QTXE150
TYPICAL INSTALLATIONS
Housing mounted to
I
-joists.
Housing mounted
anywhere between
trusses using hang-
er bars.
Housing mounted any-
where between
I
-joists
using
hanger bars.
Housing mounted to
joists.
Housing mounted
anywhere between
joists
using
hanger bars.
Housing mounted
anywhere between
trusses using hang-
er bars.
PLAN THE INSTALLATION
The unit will operate most quietly and efficiently when located
where the shortest possible duct run and minimum number of
elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce
backdrafts.
Plan to supply the unit with proper line voltage and appropriate
power cable.
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
ROOF
CAP
*
6-IN. ROUND
ELBOW(S)
*
6-IN.
ROUND
DUCT
*
WALL
CAP
*
*
Purchase
separately
INSULATION
(Can be placed
around and over
fan housing.)
FAN
HOUSING