1b. Mount housing anywhere between 

trusses, joists, or 

I

-joists using hanger 

bars.

 

 

Sliding hanger bars are provided to allow for accurate posi-

tioning of housing anywhere between framing. They can be 

used on all types of framing (

I

-joist, standard joist, and truss 

construction) and span up to 24”.

Attach the MOUNTING CHANNELS to the housing using the 

SCREWS supplied. Make sure TABS are oriented as shown. 

Use the set of mounting holes (marked “STD”) to mount the 

housing flush with the bottom of the drywall. Use the other 

set of holes (not marked) to mount the housing flush with 

the top of the drywall.

HANGER

BAR (4)

SCREWS (4)

 

Extend HANGER BARS to the width of the framing.

  Hold ventilator in place with the hanger bar tabs wrapping 

around the BOTTOM EDGE OF THE FRAMING.

  NAIL ventilator to framing or fasten with screws (not provided) 

through HOLES near nails.

 

*

 To ensure a noise-free mount: Secure hanger bars together 

with  SCREWS or use a pliers to crimp mounting channels 

tightly around hanger bars.

*

 

SCREW (2)

HOLE FOR OPTIONAL 

SCREW MOUNTING (4)

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE 

OF FRAMING

1.  Connect electrical wiring.

 

Run 120 VAC house wiring to installation location. Use 

proper UL approved connector to secure house wiring to 

wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

MODEL 66V, 66W

3-FUNCTION CONTROL (PURCHASE SEPARATELY)

LIGHT

(ON/OFF)

COM

NIGHT LIGHT

(ON/OFF)

FAN

(AUTO/OFF)

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

BLK

BLU

RED

WHT

UNIT

ORG

BLK

WHT

GRD

BLK

RED

LIGHT

NIGHT LIGHT

WHT

WHT

BLK

WHT

BRN

HUMIDITY

CONTROL

FAN

2.  Attach damper/

duct connector.

 

Snap damper / duct con-

nector onto housing. Make 

sure connector is flush 

with top of housing and 

damper flap falls closed.

3. Install 

6-inch round duc-

twork.

 

Connect 6-inch round 

ductwork to damper / duct 

connector. Run ductwork 

to a roof cap or wall cap. 

Tape all ductwork con-

nections to make them 

secure and air tight.

MODEL 77DV, 77DW

4-FUNCTION CONTROL (PURCHASE SEPARATELY)

FAN

(ON/OFF/AUTO)

120

VAC

LINE

IN

SWITCH BOX

GRD

RED

RED

BLU

UNIT

RED

BLU

WHT

GRD

WHT

BLK

BLK

RED

WHT

BLK

NIGHT LIGHT

(ON/OFF)

LIGHT

(ON/OFF)

COM

COM

BLK

BLK

WHT

ORG

WHT

BLK

WHT

BRN

HUMIDITY

CONTROL

FAN

WHT

NIGHT LIGHT

LIGHT

WIRING OPTION #1

 - Allows fan to operate in automatic mode or manual 

mode (for odor control) by cycling ON/OFF switch.

WIRING OPTION #2

 - Fan can be turned ON, OFF, or set to operate automatically.

TAB

Содержание QTXE110SFLT

Страница 1: ...ghtly vacuum to clean sensor and grille DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor OPERATION The humidity control and fan can be op erated separately Do not use a dimmer switch to operate the humidity control or light See Connect Wiring for details SENSOR OPERATION This humidity sensingfan responds to a rapid t...

Страница 2: ...away from heating or cooling sources which can affect humidity levels Do not locate near window Unit may respond to the outdoor humidity level Unit must be installed in ceiling to properly sense moisture Locate unit only on flat ceilings up to 12 feet high for proper sensing The ducting from this fan to the outside of the build ing has a strong effect on the air flow noise and energy use of the fa...

Страница 3: ...OTTOM EDGE OF FRAMING 1 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL approved connector to secure house wiring to wiring plate Connect wires as shown in wiring diagrams CONNECT WIRING MODEL 66V 66W 3 FUNCTION CONTROL PURCHASE SEPARATELY LIGHT ON OFF COM NIGHT LIGHT ON OFF FAN AUTO OFF 120 VAC LINE IN SWITCH BOX WHT GRD BLK BLU RED WHT UNIT ORG BLK WHT G...

Страница 4: ...ls or workmanship for a period of three years from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUD ING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this three year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and servic...

Страница 5: ...ALMOHADILLAS DE LANA DE ACERO NI POLVOS ABRASIVOS 3 NO USE sprays limpiadores solventes ni agua en o cerca del sensor OPERACIÓN El control de humedad y el ventilador pueden funcionar separadamente No utilice un reductor de intensidad para hacer funcionar el control de humedad o la lámpara vea los detalles en la sección Conexión eléctrica OPERACIÓN DEL SENSOR Este ventilador detector de humedad res...

Страница 6: ...rgía del ventilador Utilice el tramo de conductos más corto y recto posible para obtener un desempeño óptimo y evite instalar el ventilador con conductos menores que los recomendados El aislamiento alrededor de los conductos puede reducir la pérdida de energía e inhibir el desarrollo de moho Los ventiladores instalados en conductos existentes podrían no obtener el flujo de aire nominal 2 Planifiqu...

Страница 7: ...NIDAD CONTROL DE HUMEDAD VENTILADOR OPCIÓN DE CONEXIÓN n º 1 Permite que el ventilador funcione en modo automático o en el modo manual para el control del olor al ciclar el con mutador de ENCENDIDO APAGADO OPCIÓN DE CONEXIÓN n º 2 El ventilador se puede encenderse apagarse o ajustarse para que funcione automáticamente 1b Instale la cubierta en cualquier parte entre las armaduras viguetas o vigueta...

Страница 8: ... el número de la clave GARANTÍA LIMITADA DE TRES AÑOS DE BROAN Broan garantiza al consumidor comprador original de sus productos que tales productos estarán libres de defectos en materiales o mano de obra durante un período de tres años a partir de la fecha de la compra original NO EXISTEN OTRAS GARANTÍAS EXPRESAS NI IMPLÍCITAS INCLUIDAS PERO SIN LIMITARSE A GARANTÍAS IMPLÍCITAS DE COMERCIALIZACIÓ...

Отзывы: